––– STEP 11 –––
This guide must be stored safely and be accessible to all automa-
tion users.
11.1 –
Safety instructions
• Keep at a safe distance from the moving door until it is
completely open or closed; do not go through the door
until it is completely open and has come to a standstill.
• Do not allow children to play near the door or with the
controls.
• Keep the transmitters away from children.
11.2 – Gate control
• With radio transmitter
The radio transmitter supplied is ready for use and the four keys
have the following functions (fig. 47):
T2
47
T1
Function(*)
Key T1
Key T2
Key T3
Key T4
(*) This table must be compiled by the person who programmed
the automation.
11.3 – Manually releasing or locking the gearmotor
(fig. 49)
SL1S-SL10S are equipped with a mechanical system that ena-
bles manual opening and closing of the gate (i.e. as if there is not
a gearmotor).
The manual operation must be carried out in case of power failure
or system malfunction. In case of power failure the buffer battery
can be used (optional accessory PR1).
USER'S GUIDE
• Suspend the use of the automation immediately as soon
as you notice something abnormal in the operation (noises
or jolting movements); failure to follow this warning may
cause serious danger and accidents.
• Do not touch moving parts.
• Regular maintenance checks must be carried out by
qualified personnel according to the maintenance plan.
• Maintenance or repairs must only be carried out by quali-
fied technical personnel.
•
The selector has two positions with automatic return to the centre
(fig. 48).
T4
T3
(*) This item must be compiled by the person who programmed
the automation.
• Control with safety devices out of service
In the event of safety devices malfunctioning or out of service, the
door may still be moved.
01. Activates the gate command (with remote control or key-
02. After about 2 s the door will move in "hold-to-run" mode, in
In the event of safety devices out of service arrange for repairs to
the automation immediately.
In case of fault of the gearmotor the motor release can be used to
check whether the fault is in the release mechanism.
01. Turn the release cap cover anti-clockwise until it coincides
02. Insert the key in the release pin.
03. Turn the key anti-clockwise by about 90° until the gate is
04. Then move the gate manually.
With selector (optional accessory
48
Action
Function
Turned right: "OPEN"
(*)
Turned left: "STOP"
Stops movement of the sectional
or up-and-over door
operated selector switch). The door will open normally if there
is the consent of the safety devices, otherwise the command
must be activated and held within 3 seconds.
other words until the command is pressed the door will con-
tinue to move; the door will stop as soon as the command is
released.
with the hole with the release pin.
released.
)
29