3. Safety reverse force adjustment
4. Auto-close setting
5. Photocells setting
Press 'SET' button and hold on until the LED dis-
plays '3'.
It's under force adjustment mode. Press 'UP'
button to increase the force and 'DOWN'
button to decrease the force.
The maximum force is 9 and the minimum is 1.
Press 'SET' button to confirm.
Press 'UP' button and hold on until the LED dis-
plays '-'.
Press 'UP' button once, the auto-close time will
increase 1 minute, the maximum time is 9
minutes.
Press 'DOWN' button the auto-close time de-
crease 1 minute. The auto-close function will be
turned off when LED displays 0.
Press 'SET' button to confirm.
Press 'DOWN' button and hold on until the LED
displays'11'.
Press 'UP' button the LED displays 'H', photocells
function is available.
Press 'DOWN' button the LED displays '11' to
cancel this function.
When setting is finished, press 'SET' to confirm.
Notice: Close the photocells function if you
don't use them.