[EN] - CIRCULATOR RESIDUAL HEAD
A = Flow capacity (l/h)
B = Head (m C.A.)
1 = First speed
2 = Second speed
3 = Third speed
Residence KIS boilers are equipped with a circulator already connected to
water and electricity; see the graph for relevant available working efficiency.
The boilers are equipped with an anti-lock out system that starts up a work-
ing cycle every 24 hours of standby, with the mode selector in any position.
The "anti-lockout" system only works if the boilers have the power
switched on
It is absolutely forbidden to make the circulator work without water.
[FR] - PRÉVALENCE RÉSIDUELLE DU CIRCULATEUR
A = Débit (l/h)
B = Prévalence (m C.A)
1 = première vitesse
2 = deuxième vitesse
3 = troisième vitesse
Les chaudières Residence KIS sont équipées d'un circulateur déjà connecté
hydrauliquement et électriquement, dont les performances utiles disponibles
sont indiquées dans le graphique.
Les chaudières sont munies d'un système d'antiverrouillage qui démarre
un cycle de fonctionnement toutes les 24 heures d'arrêt, quelle que soit la
position du sélecteur de fonction.
La fonction antiverrouillage n'est active que si les chaudières sont
alimentées électriquement.
Il est strictement interdit de faire fonctionner le circulateur sans eau.
All manuals and user guides at all-guides.com
1
A
[PT] - ALTURA TOTAL DE ELEVAÇÃO RESIDUAL DA BOMBA CIRCU-
LADORA
A = Capacidade (l/h)
B = Prevalência (m C.A.)
1 = primiera velocidade
2 = segunda velocidade
3 = terceira velocidade
As caldeiras Residence KIS estão equipadas com circulador já ligado hi-
draulicamente e electricamente, cujo rendimento útil é mostrado no gráfico.
As caldeiras têm um sistema antibloqueio que prepara um ciclo de fun-
cionamento a cada 24 horas de descanso com o selector de função em
qualquer posição.
[RO] - PREVALENŢĂ REZIDUALĂ CIRCULATOR
A= debit (l/h)
B= prevalenţă (m C.A)
1 = prima viteză
2 = două viteză
3 = treia de viteză
Centralele Residence KIS sunt echipate cu o pompa de circultie, deja conec-
tata hidraulic şi electric, ale cărui prestaţii sunt indicate în grafic.
Centralele sunt dotate cu un sistem antiblocare care porneşte un ciclu de
funcţionare la fiecare 24 ore de repaus, cu selectorul de funcţie în orice poziţie.
[GR] - ΚΥΚΛΟΦΟΡΗΤΗΣ
Α= Παροχή (l/h)
Β=Διαθέσιμο μανομετρικό (m C.A
1 = Πρώτη ταχύτητα
2 = Δεύτερη ταχύτητα
3 = Τρίτη ταχύτητα
Οι λέβητες RESIDENCE είναι εξοπλισμένοι με κυκλοφορητή ήδη συνδεδεμένο
υδραυλικά και ηλεκτρικά, του οποίου οι διαθέσιμες αποδόσεις φαίνονται στο
γράφημα.
Είναι επίσης εξοπλισμένοι με σύστημα αντιμπλοκαρίσματος, το οποίο ξεκινά
έναν κύκλο λειτουργίας μετά από σταμάτημα 24 ωρών, όποια και αν είναι η
θέση του επιλογέα λειτουργίας..
2
A função "antibloqueio" vem activada somente se as caldeiras são
alimentadas electricamente.
É absolutamente proibido pôr a funcionar o circulador sem água.
Functia "antiblocare" este activa doar daca centralele sunt alimentate
electric.
Este absolut interzisă pornirea pompei de circulatie fără apă.
Το σύστημα αντιμπλοκαρίσματος είναι ενεργό μόνο αν ο λέβητας
τροφοδοτείται ηλεκτρικά.
Απαγορεύεται αυστηρά η λειτουργία του κυκλοφορητή χωρίς νερό.
RESIDENCE KIS
3
53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

28 kis cs

Table des Matières