Angelcare AC 201 Manuel De L'utilisateur page 16

Masquer les pouces Voir aussi pour AC 201:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
False alarms
Alarm will not sound
Movement Indicator Light on
Nursery Unit is flashing orange
(monitor is barely detecting move-
ment).
No sound is being transmitted.
Possible Cause
Sensor Pad cord is not connected
properly to the Nursery Unit.
Nursery Unit is detecting
movement when crib is being touched.
Nursery Unit is detecting
movement from outside the crib such as
motorized devices, strong drafts, etc.
Sensor Pad sensitivity level is set too
high.
Sensor Pad is not in full contact with crib
mattress, or the mattress is not resting
on a hard surface.
Baby is in a very deep sleep or has
moved away from Sensor Pad to the edge
of the crib.
Parents' and Nursery Units are too far
apart.
Batteries are low or improperly installed.
AC adapters are not connected properly
or electrical outlet is out of order. no está
energizado.
One of the units is not on.
Units are set to different channels.
Volume level is too low.
16
Solution
Unplug and reconnect the cord.
Avoid contact with the crib when moni-
tor is on.
Place crib near a solid supporting wall
to avoid Sensor Pad from detecting
movement from outside the crib. Turn
off crib mobile, fans, loud music or any-
thing else that may cause vibrations.
You may need to decrease the
sensitivity. Refer to the Movement
Sensitivity Adjustment section on Pg.
12.
Make sure there is no loose bedding
between mattress and the Sensor Pad.
The Sensor Pad must rest on a hard
surface. If the crib has a spring or slat
base, place a piece of Masonite meas-
uring at least 13" (33cm) on all four
sides and 1/4" (0.64cm) thick on top of
the base.
Make sure Sensor Pad is positioned
correctly in crib. The sensitivity level
may need to be adjusted. Refer to the
Movement Sensitivity Adjustment
section on page 12.
Bring Parents' Unit closer to
Nursery Unit.
Check or replace batteries.
Check connections or change
to another electrical outlet.
Make sure both units are on.
Make sure both units are on the same
channel, either both on A or B.
Increase volume level.

Publicité

Table des Matières
loading

Table des Matières