Eu Declaration Of Conformity - Güde BASIC 10T/DTS Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

EU Declaration of Conformity

We,
Güde GmbH & Co. KG
Birkichstraße 6
74549 Wolpertshausen
Germany
herewith declare that the following appliance complies with the appropriate basic safety and health requirements of the EU
Directives based on its design and type, as brought into circulation by us.
In case of alternation of the machine, not agreed upon by us, this declaration will lose its validity.
Machine description:
Basic 10T/DTS log splitter
Article No.
02040
Date/authorised signature:
07.03.2012
Title of signatory:
Managing Director, Mr Arnold
Technical documentation:
J. Bürkle FBL; QS
Applicable EU Directives:
2004/108/EG
2006/42/EG
Applicable harmonised standards:
EN 609-1/A2:2009
EN 61000-3-3:1995+A1+A2
EN 61000-3-2:2006
EN 55014-2:1997+A1
EN 55014-1:2006
Noise:
Lwa: 85,2 dB
Lpa: 69,9 dB
Troubleshooting
Problems
Possible causes
1. No current in the outlet
2. Defective extension cable
Engine not starting
3. Wrong feeder cable
4. Defective switch, condenser
Wrong engine running
1. Wrong connection
direction
1. Two-hand switching lever adjustment
Splitting knife not moving
1.
2.
3.
Splitter has no power
4.
5.
After being pressed, the
1. Defective fuse, etc.
green switching button not
2. 2 phase running
staying in place
1.
Hydraulic pump whistling;
splitting knife running jerky
2.
All manuals and user guides at all-guides.com
Wrong rotation direction
Too little hydraulic oil
Starting rod is bent; the hydraulic
lifter is not pressed to the full extent
Wood with too many knots - splitting
knife gets jammed
Operating arm is bent
Oil loss, surface is dirty
Too little hydraulic oil in the tank
Remedy
1. Check the network protection
2. Pull out the plug – check it and replace it if
necessary
3. Connection with 5 cores with a cross section of
2
2.5 mm
4. Have the appliance checked by an electrician
1. Turn the phase changer in the appliance plug
using a screwdriver
1.  Check the oil level
 Defective control valve must be replaced in a
service centre only
1. Change the rotation direction
2. Add hydraulic oil
3.  Check all screws on the starting rod
mechanism
 Adjust the pull rod (pic. 10/B); by this,
 the hydraulic lifter will be pressed to the full
extent.
4. Lubricate the splitting knife with fat.
5. Return the operating arm to the starting position.
1. Check the cable
1.  Tighten the screwing
 Replace the hoses
2. Add hydraulic oil