Speck pumpen BADU 90/40 Eco MV-E Fiche Technique page 34

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 163
Deactivating the Priming Protection in "Run Max-Flow/Vacuum" Mode
Start the pump by pressing the
1
"RUN / STOP" button. The button
should light up green.
Select the vacuum mode by
2
pressing the "Run MAX Flow /
Vacuum" button and select "Enter"
to confirm.
Once the vacuum mode has been
3
started, the "Run MAX Flow /
Vacuum" button and the arrow
button must both be pushed
upwards and held down at the
same time. In addition to this, push
the "RUN/STOP" button and hold it
down until "Press ENTER to
confirm" appears in the display.
When letting go of the buttons, let
go of the "RUN/STOP" button first.
By pushing the enter button, the
4
priming protection is deactivated
for the duration of the "Run Max-
Flow Vacuum" mode. "SVRS Off"
will appear in the display.
Do not allow anybody in the water whilst the priming protection deactivated!
34 EN
VG 766.2100.060
06/2014