Page 1
Installation and operation manual for swimming pool filter circulation pumps Instructions de montage et d’ utilisation des pompes de circulation pour installations de filtration de piscines BADU 43 BADU FAC 43 BADU FAG 43 03/ 05 VG 766.2040.050 1,5' 03/ 05 D/ GB/F - BA...
Pumpen aus Kunststoff, im Sinne der EG-Maschinenrichtlinie 89 / 392 / EWG, Anhang II A Baureihe BADU 43, BADU FAC 43 und BADU FAG 43 as defined by machinery directive 89 / 392 / EEC, Annex II A conformément à la directive CE relative aux machines 89 / 392 / CEE, Annexe II A Hiermit erklären wir, dass das Pumpenaggregat...
Page 3
Baureihe BADU 43, BADU FAC 43 und BADU FAG 43 Ursprungsland : Bundesrepublik Deutschland Einsatzbereich : Die Schwimmbadpumpen BADU 43, BADU FAC 43 und BADU FAG 43 sind ausschließlich zur Umwälzung des Schwimmbadwassers in Verbindung mit einer Schwimmbad - Filteranlage einzusetzen.
Page 4
3~Y/6 400/230 V 0,75 1,00 1,50 1,50 Nennstrom (A) 3~Y/6 400/230 V 2,10 / 3,60 2,50 / 4,30 3,30 / 5,70 3,30 / 5,70 Gewicht (kg) BADU 43 12,2 15,8 16,5 16,5 Gewicht (kg) BADU FAC 43 13,5 17,1 17,8 17,8 Maß~L...
Sicherheit 2.2 Personalqualifikation und -schulung Diese Betriebsanleitung enthält grundlegende Hinweise, die bei Aufstellung, Das Personal für Bedienung, Wartung, Inspektion und Montage muss die ent- Betrieb und Wartung zu beachten sind. Daher ist diese Betriebsanleitung unbe- sprechende Qualifikation für diese Arbeiten aufweisen. Verantwortungsbereich, dingt vor Montage und Inbetriebnahme vom Monteur sowie dem zuständigen Zuständigkeit und die Überwachung des Personals müssen durch den Betrei- Fachpersonal/Betreiber zu lesen und muss ständig am Einsatzort der Maschi-...
Die Pumpe muss horizontal und trocken aufgestellt werden. Die Baureihe BADU 43 ist normalsaugend und darf deshalb nur unterhalb des Wasserni- Die Kunststoffpumpen der Baureihe BADU 43, BADU FAC 43 und BADU FAG veaus (Zulaufbetrieb, max. 3 m) montiert werden. In der Saugleitung ist ein Ab- 43 sind zur Umwälzung des Schwimmbadwassers in Kombination mit einer ent-...
Page 7
Uhrzeigersinn). Ist dies nicht der Fall, unbedingt einen Fach- ACHTUNG ! mann rufen ! (Zwei Phasen tauschen). Für BADU 43 : Absperrschieber in der Saugleitung öffnen, oder bei Saugleitung mit Fußventil ACHTUNG ! die Pumpe und die komplette Saugleitung bis zum Druckanschluss mit Wasser Bitte darauf achten, dass die eingebauten Absperrorgane in Saug- und Druck- füllen.
Page 8
Pumpe kann Motorschäden zur Folge haben. In diesem Fall erlischt der Garantieanspruch ! ACHTUNG ! Bei Frostgefahr ist die Pumpe rechtzeitig zu entleeren. Bei der BADU 43 eine ACHTUNG ! Verschlussschraube (903) und bei der BADU FAC 43 und BADU FAG 43 beide Der Leckageabfluss unten zwischen Pumpengehäuse und Motor darf nicht ver-...
Page 9
Zeit zu Zeit einige Tropfen Wasser austreten, vor allem während der Einlauf- Ersatzteilzeichnung zeit. Je nach Wasserbeschaffenheit und Betriebsstundenzahl kann diese Dich- BADU 43 tung im Lauf der Zeit undicht werden. Wenn laufend Wasser austritt, ist eine neue kpl. Gleitringdichtung (433) einzubauen (siehe 7.5).
Page 10
Ersatzteilliste mit Werkstoffen für BADU 43 9. Zugehörige Unterlagen 43/15, 43/21, 43/26, 43/32 Ersatzteilzeichnung Teil Stück Benennung Werkstoff BADU FAC 43 Bemerkung Druckgehäuse (Druck Rp 2) PP TV 20 / GF 10 Zwischengehäuse PP GF 30 161.1 Dichtungsgehäuse PP GF 30 43/32 161.2...
Page 11
Ersatzteilliste mit Werkstoffen für BADU FAC 43 9. Zugehörige Unterlagen FAC 43/15, FAC 43/21, FAC 43/26, FAC 43/32 Ersatzteilzeichnung Teil Stück Benennung Werkstoff Bemerkung BADU FAG 43 Druckgehäuse (Druck Rp 2) PP TV 20 / GF 30 Zwischengehäuse PP GF 30 Filtergehäuse PP TV 20 Saugsieb kpl.
Ersatzteilliste mit Werkstoffen für BADU FAG 43 FAG 43/15, FAG 43/21, FAG 43/26, FAG 43/32 Teil Stück Benennung Werkstoff Bemerkung Druckgehäuse (Druck Rp 2) PP TV 20 / GF 10 Zwischengehäuse PP GF 30 Filtergehäuse PP TV 40 Saugsieb kpl. mit Griff Deckel PC Makrolon 2807 161.1...
Page 13
Country of Origin: Federal Republic of Germany Range of Application: The swimming pool pumps BADU 43, BADU FAC 43 and BADU FAG 43 have been exclusively designed for the circulation of swimming pool water in combi- nation with a swimming pool filter unit.
Safety 2.2 Personnel Qualification and Training All operation, inspection and installation personnel must be qualified for these The Operation Manual contains basic instructions which must be obeyed during jobs. Scope of responsibility, competency and the supervision of the personnel mounting, operation and maintenance. Therefore, the Operation Manual should must be clearly defined by the operator.
Page 16
Safety marking; Safety symbol W 8 the strainer basket (143), towards above the minimum space required is as Supplement 13 follows: min. 260 mm with BADU 43, min. 220 mm with BADU FAC 43, see DIN 4844 Part 1 Safety marking; Safety symbol W 9 directions in the dimensional drawings.
Page 17
If the motor rotates in the wrong direction, two phases must be swit- ched (by a licensed electrician only!). For BADU 43 : Open shutoff valve in the intake line or in case of intake line with foot valve to-...
Page 18
If there is danger of freezing, the pump must be drained ahead of time. With the BADU 43 open one drain plug (903) and with the BADU FAC 43 and the BADU The leakage pipe on the underside between pump housing and motor must FAG 43 open both drain plugs (903) and let the water drain from the pump.
Page 19
Malfunction You will find the parts drawings as well as the The sealing between the motor and the pump housing is done by means of a parts lists on the following pages. mechanical seal (433). If once in a while a few drops of water seep through this is not a cause for concern especially during the break-in period.
9. Associated documentation Parts List and Materials for BADU 43 43/15, 43/21, 43/26, 43/32 Parts drawing Serial Qty. Description Material BADU 43 remark Pressure casing (outlet connection Rp 2) PP TV 20 / GF 10 Flange PP GF 30 161.1...
Page 21
Parts List and Materials for BADU FAC 43 9. Associated documentation FAC 43/15, FAC 43/21, FAC 43/26, FAC 43/32 Parts drawing Serial Qty. Description Material remark BADU FAC 43 Pressure casing (outlet connection Rp 2) PP TV 20 / GF 10 Flange PP GF 30 Strainer tank...
Page 22
Parts List and Materials for BADU FAG 43 FAG 43/15, FAG 43/21, FAG 43/26, FAG 43/32 9. Associated documentation Parts drawing Serial Qty. Description Material remark BADU FAG 43 Pressure casing (outlet connection Rp 2) PP TV 20 / GF 10 Flange PP GF 30 Strainer tank...
Page 23
Pays d’origine : Allemagne Domaine d’application : Les pompes pour piscines BADU 43, BADU FAC 43 et BADU FAG 43 sont exclusivement destinées à la circulation de l’eau dans les piscines, raccordées à une installation de filtration appropriée, ou à un dispositif de nage à contre- courant.
Sécurité 2.3 Danger en cas de non-respect des instructions en matière de sécurité : La présente notice contient des instructions de base qui doivent être respec- Le non-respect des instructions de sécurité peut non seulement mettre en dan- tées au moment de l’installation, de l’utilisation et de l’entretien de la pompe. Il ger la vie des personnes, mais également provoquer des dégâts à...
La pompe doit être installée à l'horizontale et au sec. La série BADU 43 est non sentent de ce fait une excellente résistance à la corrosion par l’eau de la pisci- auto-amorçante et pour cette raison peut être montée uniquement en dessous...
Page 27
ATTENTION ! Lors de la première mise en service de pompes équipées de moteurs tri- Type BADU 43 : phasés, veiller à ce que le moteur tourne dans le sens de la flèche signalée sur Ouvrir le clapet anti-retour installé sur la conduite d’aspiration. En cas de con- la pompe (en direction du ventilateur, dans le sens des aiguilles d’une montre).
ATTENTION ! ATTENTION ! Veillez à ce que les vannes d’arrêt installées sur les conduites d’aspiration et Un écoulement d’eau, provoqué par une fuite entre le corps de pompe et le mo- de refoulement soit totalement ouvertes lors de la mise en service, la pompe ne teur ne doit pas être obstrué...
Page 29
En cas de risques de gel, ne pas oublier de vidanger la pompe en temps oppor- suivantes. tun. Pour le type BADU 43, desserrer la vis de purge (903), et pour le type FAC 43 et FAG 43, desserrer les deux vis de purge (903) et laisser s’écouler l’eau du corps de pompe.
9. Documents annexes Pièces de rechange BADU FAC 43 et matériaux FAC 43/15, FAC 43/21, FAC 43/26, FAC 43/32 Vue éclatée BADU FAC 43 Matériaux Pièce Qté. Désignation Remarques Corps de pompe (raccord aspiration Rp 2) PP TV 20 / GF 10 Bride pompe / moteur PP GF 30 Corps de pré-filtre...