Setting the timer programs (Custom Flow 1...4)
1
The programming interface is
accessed by pressing the
"Program Menu" button. Select the
timer programs – Custom Flow 1 –
using the arrow button. Press the
"Enter" button to edit them.
Settings can only be made when
the pump is in stand-by mode.
2
When "Custom Flow" flashes,
toggle between the four programs
using the arrow buttons (up/down)
and set the run time and the
volumetric flow using the arrow
buttons (left/right).
Volumetric flow: (0), 30-100%
Timer period: 10-249 minutes
3
After timer programs 1 to 4 have
been set, save them by pressing
the "Enter" button.
4
Press the "Exit" button to return to
stand-by mode. The suitable
program can be selected by
pressing the "RUN / STOP" button.
The "Enter" button is used to start
the program.
06/2014
VG 766.2100.060