Knobs

YOUR APPLIANCE

Automatic Safety Valve
These hobs have a safety device that automatically closes
the gas cock if the flame accidentally goes out due to
draughts, a pot spilling over, or a temporary interruption
of the gas supply. This device is activated approx. 30
seconds after the flame goes out.
Burner use
For lower gas consumption and better efficiency use pots
of widths suitable for the burners, making sure the flame
does not go beyond the edges (comply with the table
below).
Ensure that the room is well ventilated.
X
X

OPERATION

Lighting the burners

The hob is lit with the control knobs. To light the burners,
proceed as follows:
Press and turn the required knob to the lighting and
X
X
max delivery position.
Keep the knob pressed down for 3-4 seconds to allow
X
X
the sparks to ignite the gas coming out the flame
spreader and to allow the thermocouple to heat up.
Then release the knob and, turning it anticlockwise
X
X
adjust the flame as required. If the flame does not
stay alight, repeat the operation from step 1.
FH CR 301 1TC / FH CR 302 2G / FH CR 604 4G /
FHCR 755 4G TC / FHCR 905 4G TC / FHCR 1204 3G TC
– 8 –
Knob icon
Burner
Pan bottom min-max. Ø
AUX
SR
SR PLUS
R
TC
The use of larger pots than those specified can cause
excessive overheating of the knobs and top and, in case
of prolonged use, yellowing of the cover (if in stainless
steel).
FRANKE declines any liability for damage due to such use.
Function
Off
Minimum delivery
Lighting and maximum delivery
(recommended)
60 -140 mm
120 - 200 mm
120 - 200 mm
150 - 240 mm
180 - 260 mm