10. TECHNICAL SPECIFICATIONS

In line with Decree No. 2/1984 (III.10.) BkM-IpM, it is certiied that our
appliances conform to the following technical speciications.
Intended use
Placement
Volume
Voltage
Protection grade
Heating power
Heater type
Current input
Heat-up time from 15 ºC to 65 ºC
Standby energy consumption
Water connection
Nominal operating pressure
Safety valve highest opening pressure [MPa]
Integrated safety and regulator elements
Other protection
Contact protection rating
Main regulations applicable to the product
Storage and transport requirements
44
Model
[kWh/24h]
[MPa]
C80S
C50S
Closed system rectangular hot water
storage tank
Wall mounted vertical
[L]
50
80
[V]
[W]
1200
[A]
6
[h]
2.63
2.11
0.94
1.1
G1/2
Electronic temperature regulator,
electromechanical temperature limiter,
combined safety valve
Corrosion protection with active anodes
Msz en 60335-1, Msz en 60335-2-21
Msz en 60721-3
C120S
C150S
C200S
120
150
200
230V/50Hz
IP X4
2400
ceramics
11
3.16
3.95
5.27
1.38
1.56
G3/4
0.6
0.7
I.
1.6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C80sC120sC150sC200s2111614811

Table des Matières