LERBAKKEN 10, 8410 RØNDE DENMARK.
Non Incendive installation:
Hazardous classified Location
Class I,II,III ,Division 2, Groups, ABCDFG
Class I, Zone 2, IIC
T4: -20/-40 ≤ Ta ≤ 85ºC
T6: -20/-40 ≤ Ta ≤ 60ºC
Terminal: 3,4,5,6
Sensor: RTD or TC
O-ring Sealings
Silicone rubber:-40°C ≤Ta ≤ +85°C
FKM rubber:
Protection: Indoor and Outdoor TYPE 4X or IP66
Revision date:
2016-08-03
56
6
+
1
5
-
2
4
3
7501
-20°C ≤Ta ≤ +85°C
Version Revision
V5R0
7501V108-FR
WWW.PRELECTRONICS.COM
Non classified Location
Vmax
35V
Terminal: 1,2
Vmax: 35 VDC
7501QF01
Page: