OPERATION DURING A POWER OUTAGE
The handle cannot be operated during a power outage. Use the manual operating valve instead.
1) To start the water:
Turn the valve
clockwise.
Clean the parts regularly to prevent the accumulation of dirt and lime-scale.
For daily cleaning, use a neutral cleaner.
Acids are necessary ingredients of cleaning materials for removing lime. However, please pay attention to the follow-
ing points when cleaning fittings:
• Only use cleaning materials which are explicitly recommended for this type of application.
• Never use cleaning materials which contain hydrochloric, formic or acetic acid, as they may cause considerable
damage.
• Do not use phosphoric acid as it can also cause damage.
• Never use cleaning materials or appliances with an abrasive effect, such as cleaning powders, sponges or microfi-
ber cloths.
Please follow the cleaning material manufacturer's instructions. In addition, pay attention to the following points:
• When using spray cleaners, spray first onto a soft cloth or sponge. Never spray directly onto the fittings, as drops
could enter openings and gaps, which can then cause damage.
• After cleaning, rinse thoroughly with clean water to remove any cleaner residue.
Components with damaged surfaces must be exchanged, otherwise this can cause an injury. Damage caused by
improper treatment will not be covered by our warranty.
Check the flashing light pattern of the handle and refer to the following table:
Flashing
Problem
Pattern
Red flashing
Hot water
(2 times per
temperature is
second)
extremely high
Pink flashing
Malfunction of
the controller.
Blue flashing
• Operating pressure range:
- Recommended:
• Hot water supply temperature:
(Refer to your local code for the maximum allowed temperature)
• Cold water supply temperature:
• Discharge water temperature:
• Flow rate:
(Refer to the "How To Use" section in this manual)
• Supply voltage:
• Waterproof specifications:
• Water inlet:
E
Operation of the Manual Operating Valve
CLEANING AND CARE
ERROR INDICATIONS
Solution
Wait for a moment and then press the handle again.
• If the hot water temperature exceeds 122°F, the water will stop automatically.
• Operation is not possible until the water temperature in the controller is lowered.
Disconnect the main plug and then reconnect it.
If the flashing continues, request a repair.
SPECIFICATIONS
2) To stop the water:
Turn the valve
counter-clockwise.
Min: 10 psi (0.07 MPa) flow pressure
Max: 80 psi (0.55 MPa) static pressure
7
30 psi-44 psi (0.2-0.3 MPa)
120°F-180°F (49°C-82°C)
39°F-80°F (4°C-27°C)
93°F-112°F (34°C-44°C)
1.3 gpm (5 lpm) or 2.0 (7.6 lpm)
AC 100-240 VAC (50/60 Hz)
IPX3 (handle)
IPX3 (controller)
1/2" NPSM