UTO
ORMULA
For use with computer controlled (intelligent) host machines
only, the Auto Formula Select mode allows automatic selection
of programs (formulas) without the need for a Formula Select
module.
To Activate:
The
AUTO FORMULA SELECT MODE
automatically when the first signal to the unit (after it has reset)
is to input 6.
After receiving the signal to input 6, the host machine then has
30 seconds to signal the unit with the desired program number.
This is done by signalling the inputs 1-5, and works on a binary
basis: -
1
Input 1 = Binary
2
Input 2 = Binary
4
Input 3 = Binary
8
Input 4 = Binary
16
Input 5 = Binary
(All signals must be present for the duration of the signal
acceptance time. See page 24)
Example 1:
If program number 10 is needed, the host machine must signal
inputs 2 and 8 within 30 seconds of signalling input 6.
2
Input 2 = Binary
8
Input 4 = Binary
2 + 8 = 10, so program 10 will be selected.
Example 2:
If program number 15 is needed, the host machine must signal
inputs 1,2,3 and 4 within 30 seconds of signalling input 6.
1
Input 1 = Binary
2
Input 2 = Binary
4
Input 3 = Binary
8
Input 4 = Binary
1 + 2 + 4 + 8 = 15, so program 15 will be selected.
After the 30-second time delay, the unit will display the selected
program number in the top right corner of the screen.
The inputs can then be signalled, and the pumps will run as
normal, in the selected program.
After the unit has reset (see page 32), the program number will
revert to 01.
Note:
If a unit receives a combination of signals which is in excess of
the maximum number of programs (e.g. input 4 + input 5
= 8 + 16 = 24) an error message will be shown on screen (see
opposite) and the unit will default to program 01.
B