Télécharger Imprimer la page

Brightwell Brightstar II Mode D'emploi page 30

Publicité

Les langues disponibles

Les langues disponibles

P
ROGRAMMING
From the INPUT SELECTION screen, press the
FWD/ACCEPT
key to move to the PULSE COUNT screen.
The PULSE COUNT setting allows the user to select the
number of signal pulses required by the displayed input, before
the pump will run.
This is useful when (for example) a solenoid gives more than
one signal during a cycle. In this case, if the unit were to run on
every input signal, it would run several times during the wash
cycle.
The unit can therefore be set to run on the first of the signals,
the fourth, or any number up to 99, in order to avoid this multi-
triggering.
Note:
In most circumstances the pulse count will be set to 01.
The unit can also be set to run on ALL pulses.
When set to ALL, the pump will run on every signal to the
displayed input.
In order to check the pulses being received by each input
during a wash cycle, the BrightStar unit provides a pulse test
facility (see page 41). This must however be used before any of
the pumps have been "enabled", with all of the pulse counts set
to "ALL" (default).
Example:
If the pulse count is set to 01, the pump will run when the first
signal is received. All further signals to the displayed input will
be ignored until the unit has re-set (see page 32)
Setting:
UP
DOWN
Use the
and
for the displayed input.
FWD/ACCEPT
Press the
move to the first of the PUMP SETUP screens.
Caution:
If the pulse count of a pump is set to all, multi triggering may
occur with some laundry machines.
B
L
S
RIGHTSTAR
AUNDRY
YSTEMS
-
P
ULSE
keys to select the required pulse count
key to confirm the selection and
C
OUNT
.
29
PROGRAM 01
SET INPUT 01
PULSE COUNT
001
E
NGLISH
PROGRAM 01
SET INPUT 01
PULSE COUNT
All
PROGRAM 01
SET INPUT 01
SET PUMP 01
DISABLE
B
L
S
RIGHTSTAR
AUNDRY
YSTEMS