10. Testez IPMP en retirant temporairement un SSC du châssis.
Les messages d'erreur suivants apparaîtront sur la console :
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: The link has gone down on bge3001
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: NIC failure detected on ce3001 of group medusa_grp0
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: Successfully failed over from NIC bge3001 to NIC bge3000
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: The link has gone down on bge3003
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: NIC failure detected on bge3003 of group medusa_grp0
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: Successfully failed over from NIC bge3003 to NIC bge3002
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: The link has gone down on bge2001
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: NIC failure detected on bge2001 of group medusa_grp0-mgt
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: Successfully failed over from NIC bge2001 to NIC bge2000
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: The link has gone down on bge2003
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: NIC failure detected on bge2003 of group medusa_grp0-mgt
Nov 24 16:43:15 medusa-s1 in.mpathd[108]: Successfully failed over from NIC bge2003 to NIC bge2002
Il faut environ 10 secondes au démon IPMP pour détecter et se reprendre d'une
panne réseau avec la configuration par défaut. La configuration du démon IPMP
est définie dans le fichier /etc/default/mpathd.