schmalz SCPSi-UHV-HD Notice D'utilisation page 70

Table des Matières

Publicité

IO-Link Data Dictionary
21.10.01.00065/02
Predictive Maintenance [PM]
Leakage rate
160
0x00A0
161
0x00A1
Free-flow vacuum
162
0x00A2
Quality
163
0x00A3
Performance
Diagnostic Buffer
131
0x0083
Diagnostic buffer (all entries)
132
0x0084
Diagnostic buffer (newest)
EPC Data Buffer
133
0x0085
EPC data buffer (all entries)
EPC data buffer (newest)
134
0x0086
J. Schmalz GmbH
2 bytes
ro
2 bytes
ro
1 byte
ro
1 byte
ro
228 bytes
ro
6 bytes
ro
100 bytes
ro
10 bytes
ro
7 of 11
SCPSi series
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
Leakage of last suction cycle (unit: 1 mbar/sec)
Last measured free-flow vacuum (unit: 1 mbar)
Quality of last suction cycle (unit: 1 %)
Last measured performance level (unit: 1 %)
Newest 38 entries in the diagnostic buffer (encoding see table below)
Newest entry in the diagnostic buffer (encoding see table below)
Newest 10 entries in the EPC data buffer
(encoding see table below)
Newest entry in the EPC data buffer (saved at last autoset)
(encoding see table below)
29.08.2014
SCPSi Data Dictionary

Publicité

Table des Matières
loading

Table des Matières