NOTES TO BE TAKEN INTO ACCOUNT IN ACCORDANCE WITH UNE-EN 30-1-1 February 1999

1.- Before the installation, make sure that the premises distribution conditions (gas nature
and pressure) and the adjustment of the appliance are compatible. Page 88 of the
standard.
2.- This appliance adjustment conditions are written on the label (or characteristics plate).
Page 88 of the standard.
3.- This appliance should not be connected to an extractor device of the combustion
products. Its installation and connection must be carried out in accordance with the
current installation regulations. Special attention must be made to the regulations
applicable to ventilation. Page 88 of the standard.
4.- The use of a gas cooking appliance produces heat and humidity in the premises where it
is installed. Adequate ventilation of the kitchen should be ensured: keep the natural
ventilation orifices open or install a mechanical ventilation device (extractor fan). Page
91 of the standard.
5.- An intense and prolonged use of the appliance can require supplementary ventilation,
for example, opening a window, or a more efficient ventilation increasing the
mechanical ventilation power, if existing. Page 91 of the standard.
6.- In the glass ceramic hob lower part cabinet no bottles or recipients with inflammable or
volatile, caustic or acid products should be stored, as they may damage the metal parts
and piping of the plate, both those of gas and electricity, as well as the control elements.
7.- When an oven is installed under the hob, the perforated cover at the end of the same
should be removed.
8.- If this gas glass ceramic hob is installed with an oven making up a functional group,
whether it is a gas or electric oven, this should be with the models authorised by
Vitrokitchen and tested in an official laboratory.
TECHNICAL CHARACTERISTICS:
Gases: Natural Gas - Pressure 20 mbar. Regulated
Butane
Propane
Burners : Heat Source A: 2 of 2 gas powers, 2.55 Kw ( 2.200 Kcal /h )
Heat Source B: 2 of 2 gas powers, 2.07 Kw ( 1.780 Kcal /h )
Heat Source C: 1 of 1 Gas powers, 0.70 Kw ( 600 Kcal /h )
Category :
II 2H3+
Class : 3
Nominal heat consumption : Natural Gas: 5´320 Kw (4.575 Kcal/h)
Total consumption :
PARTIAL CONSUMPTION AND GAS POWER : INJECTOR DIAMETERS
HEAT
BURNER
SOURCE
Crown
A
Central Burner
Sequential Crown
B
Mini Central
Burner
C
Auxiliary Burner
GLASS GAS CERAMIC HOB: "TOUCH GAS"
- Pressure 28 mbar.
- Pressure 37 mbar.
2.085 Kw (1.793 Kcal /h)
G.L.P. : 5´335 Kw (4.592 Kcal/h)
Natural Gas (G-20) = 0.51 m
Butane Gas (G-30) = 387 grs/h
Propane Gas (G-31) = 380 grs/h
GAS POWER
Kw
Kcal/h
1.62
0.93
1.92
0.150
0.165
0.70
G 20 ... Natural Gas = 9.050 Kcal / m
G 30 ... Butane = 11.850 Kcal / Kg.
G 31.... Propane = 12.000 Kcal/Kg.
3
/h
GAS CONSUMPTION
But. Gr./h. Prop.
1,400
119
800
68
1.650
140
129
---
141
12
600
51
14
3
φ INJECTORS
ln / h
N.G.
G.L.P.
117
154
0.63
66
89
0.49
137
183
0.68
---
14
0.19
12
---
50
67
0.40
N.G.
0.95
0.69
1.01
0.30
0.64