3. Installation of mains plug
A qualified electrician must install a suitable mains plug. The correct supply voltage is
shown in section 2.2.
The wires should be connected as follows:
TIH 030m/230V, TIH 030m/110V
Colour of TIH 030m wire
yellow / green
blue
brown
Verify that the correct fuse is installed. See section 2.2 for fuse rating specifications.
4. Preparation for use
•
Place the TIH 030m in the horizontal position on a stable surface.
•
Connect the mains plug to a suitable mains supply.
•
Plug the remote control into the connector on the carrying handle side of the heater.
•
For workpieces with an internal diameter large enough to fit over the inductive coil,
follow these steps:
- Place the workpiece over the inductive coil using appropriate lifting equipment.
- For best performance, adjust the position of the workpiece so that the
inductive coil is in the centre.
- Position the largest yoke so that it completely covers the top of both vertical
supports.
•
For workpieces that do not fit over the inductive coil, follow these steps:
- Choose the largest of the three yokes that fit through the internal diameter
of the workpiece.
- If necessary, remove the top yoke from the TIH 030m.
- Slide the workpiece onto the yoke that you have selected.
- Position the yoke on the TIH 030m with the bright underside resting evenly
on the two vertical supports.
•
If you will use TEMP MODE, plug the temperature probe into the connector on the
carrying handle side of the heater. Place the magnetic end of the probe on the inner
ring of the bearing or on the innermost surface of the workpiece.
•
Switch on the TIH 030m.
•
Observe the self-test of the remote control display and signal tone.
8
Mains supply terminal
ground
neutral
phase 1
SKF TIH 030m