Venting And Horizontal Termination Requirements - Kozy Heat Fireplaces ALP-36 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3 Venting and Horizontal
Termination Requirements
If a pipe configuration includes a vertical component that goes
downward, a vertical component going back upward is not allowed.
The #KPV System must terminate horizontally.
Use Table 2.1 for venting guidelines. Use Figure 2.5 for a guide to
calculate total vent run. Termination must be in shaded area.
Maximum Elbows
(8) 90° or (16) 45°
Shown with the Callaway-40
Figure 2.5, Horizontal Termination Guide
6 VENTING
Table 2.1, KPV Venting Guidelines
Maximum Total Horizontal
Maximum Vertical Vent Run
Vent Run
60' (18.3 m)
60' (18.3 m)
Do not exceed 60'
Do not exceed 60'
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
No vertical rise is required with #KPV. The venting can run
horizontal directly off the appliance.
Maximum Vertical Drop
Allowed
8' (2.4 m)
For every 1' (30 cm) of vertical
drop the maximum total vent
run is reduced by 2' (61 cm)
Maximum Total Vent Run
100' (30 m)
Kozy Power Vent #KPV R.5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Bhm-52Clw-40Clw-50Clw-72Sfd-36

Table des Matières