Kozy Heat Fireplaces ALP-36 Manuel D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.
The power vent wire harness has the black hot wire split with
two female quick connections on either end. Plugs these into the
black leads that have quick connections coming off the control
module in the X12 combustion blower location. See Figure 4.7.
5.
Locate the blue looped wire on the control module wire harness
that connects to the IPI/CPI location on the control module. Cut
this looped wires so you have two individual blue wires.
6.
Locate the yellow looped "APS" wire on the control module wire
harness. Cut this looped wire for two individual yellow wires.
Strip back approximately 1/2" of the end of each wire. Using the
(2) provided blue wire nuts, twist one of the yellow APS wires
into the brown wire coming from the vacuum switch in the
power vent assembly. Use the second blue wire nut to twist the
second yellow APS wire to the red wire coming from the vacuum
switch as shown in Figure 4.8.
7.
Run the other end of the power vent wiring to the power vent
termination assembly. For attaching the wire harness to the fan
and vacuum switch, refer to Section 3.5 on page 11.
8.
Connect the three prong plug into the electrical box in the
fireplace.
Figure 4.7, Quick Connections to Black Leads
Figure 4.8, APS Wire Nuts
18 ELECTRICAL INFORMATION
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Kozy Power Vent #KPV R.5