4.1.2 Wiring the KPV to the Appliance
NOTE: Use Figure 4.9 (pg. 19) as wiring schematic references when
following the individual instructions below.
1.
Depending on your vent termination location, there are (2)
power vent wire harness holes, one on either side of the unit. The
power vent wire harness holes are located on a removable plate.
Remove screws that attach the plate to the outer shell for easier
access. Reattach the plate when finished. See Figure 4.4.
2.
Run the loose wiring through the larger section of the opening
until you reach the start of the flexible conduit. Unscrew the nut
from the conduit end and slide the conduit end into the smaller
section of this opening. Screw the locking nut back on the
threads of the conduit securing it to the fireplace. See Figure 4.5.
3.
Locate the Power Vent IFC wire harness in the components
packet. Plug the connector into X12 and X13 plug receptor. See
Figure 4.6.
Instructions continue on the next page.
Removable Plate
Power Vent Wire Harness Hole
Right Side of Unit
Gas Line Access Hole
Figure 4.4, Power Vent Wire Harness Hole Location
Kozy Power Vent #KPV R.5
Electrical Access
Power Vent Wire Harness Hole
Left Side of Unit
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Figure 4.5, Run Wiring through Opening and Secure
Figure 4.6, Power Vent IFC Wire harness and X12 & X13 Location
ELECTRICAL INFORMATION 17