4.0 ELECTRICAL INFORMATION

4.1 Wiring to the Appliance

NOTE: Electrical wiring must be done in accordance with national,
provincial, and/or local electrical codes.
WARNING: Disconnect electrical power from fireplace/power vent
before performing any maintenance, repair, or electrical wiring.
NOTE: Electrical service of 120 VAC-60Hz must be supplied to the
junction box of the fireplace in order for the power vent to operate
correctly. The current draw of this device is 0.85 amperes.
Ensure that the proper clearances are maintained for wiring and
conduit. When installing the wiring, it must never run above the vent
run and it must be a minimum 1" from all venting.
The battery back up will not run with power venting installed.
4.1.1 Prepare Control Board
1.
Remove the control board from housing (2) screws, and
disconnect all wires.
2.
Use a flat blade screwdriver to pry the tabs of the top cover of
the control module to release.
3.
Locate the JP1 jumper. It is a small plastic jumper that connects
two pins as shown in Figure 4.2.
4.
Pull the plastic jumper straight up to expose the two individuals
pins underneath it. This changes the control module function
from a natural draft system to a power vent system. See Figure
4.3.
5.
Reinstall control module top cover. Plug in all components
previously unplugged.
Figure 4.1, Remove Control Board Cover