Télécharger Imprimer la page

steute RF 96 LT SW868 Instructions De Montage page 4

Masquer les pouces Voir aussi pour RF 96 LT SW868:

Publicité

RF 96 LT SW868/SW915/SW917/SW922
//
Montage- und Anschlussanleitung / Reflexions-Lichttaster
Mounting and wiring instructions / Reflective light-sensor
Instructions de montage et de câblage / Détecteur de lumière réfléchie
Istruzione per il montaggio e per il collegamento / Sensore ottico
Instruções de montagem e instalação / Sensor de luz refletiva
Инструкция по монтажу и подключению / Диффузионный оптический датчик
English
Maintenance and cleaning
With rough conditions, we recommend routine maintenance as follows:
1. Removal of all dirt particles.
2. Remove dust from sensor surfaces.
Clean enclosure on the outside only. Clean enclosure with household
cleaning agents. Do not use compressed air to clean.
Technical information
The infrared transmitters and receivers in steute reflection light
sensors are located next to each other behind a filter in the housing
cover, both pointing upwards. A short infrared flash is emitted approx.
5 times per second. Reflective light sensors detect an object as soon
as they sense sufficiently reflected light from its surface. When an
object is detected, the sensor generates a defined electrical output
signal. A light surface reflects more light than a dark surface and can
therefore also be detected from a greater distance. In order to achieve
similar results with a dark background, the sensitivity of the sensor
must be high. It is a challenge with optical sensors to detect a small
dark object against a light background. Due to the high level of reflec-
tion, the background can outshine the object, making it difficult to see.
Conversely, light objects against a dark background are much easier
to detect. In order to save energy in this battery-driven product and to
prolong the battery lifetime, the pulsing of the infrared transmitting
diode is relatively long, at approx. 5 Hz. This also, however, leads to
an increased response time. The sensor technology in the RF 96 LT
SW868/SW915/SW917/SW922 has been shown to react sensitively to
the light scatter from flashing warning lights using xenon gas-dis-
charge lamps. If necessary, appropriate shading must be provided
on site.
Battery
When the battery voltage acc. to the radio protocol drops below approx.
<3200 mV (at 20°C, load approx. 20 mA), it may be assumed that the
battery is empty. Attention: The open circuit voltage measurement
does not provide reliable information! In order to ensure reliable func-
tioning, the battery must be replaced. To do this, the 5 screws in the
housing cover must be opened using a torx-8 screwdriver. The battery
should be inserted in the direction shown by the symbols on the cover.
Use only the designated battery type or a complementary battery
type. Depending on the country the device is supplied to, delivery will
include an AA lithium battery SL-760/3.6 V/2.2 Ah in a battery adapter,
or a lithium battery SL-2770/3.6 V/8.5 Ah without an adapter or a com-
plementary battery type.
Spare part:
Name
Lithium battery SL-2770/S 3.6 V/8.5 Ah
Lithium battery SL-760 (3.6 V/2.2 Ah AA)
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately. Dispose of possibly contained
batteries correctly.
N.B.
The described products have been developed in order to assume
functions as part of an entire plant or machine. It is the responsibility
of the manufacturer of a plant or machine to guarantee the correct
general function. Subject to technical modifications. Reconstruction
and alterations to the device are not allowed. steute does not assume
any liability for recommendations made or implied by this description.
New claims for guarantee, warranty or liability cannot be derived from
this document beyond the general terms and conditions of delivery.
ESD
Ensure adequate ESD protection for all work that requires opening
the unit.
Français
Utilisation des instructions de montage et de câblage
Groupe cible : personnel autorisé et compétent.
Toutes les manipulations décrites dans cette notice d'installation ne
doivent être effectuées que par du personnel formé et autorisé par la
société exploitante.
1. Lire et comprendre les instructions de montage et de câblage.
2. Respecter les règles de sécurité et de prévention des accidents
en vigueur.
3. Installer l'appareil et le mettre en service.
La sélection et l'installation des appareils et leurs intégrations dans
les systèmes de commande exigent une connaissance approfondie
de toutes les lois pertinentes, ainsi que des exigences normatives du
fabricant de la machine. En cas de doute, la version allemande fait
référence.
Volume de livraison
1 appareil, 1 instruction de montage et de câblage, carton.
Utilisation conforme
Le RF 96 LT SW868/SW915/SW917/SW922 est constitué essentielle-
ment de trois parties: l'alimentation en énergie par pile au lithium, le
capteur infrarouge à réflexion et la partie radio avec interface intégrée
pour la technologie des capteurs. L'alimentation en énergie est fournie
par une pile 3,6 V au lithium-chlorure de thionyle non rechargeable.
Lors d'une réflexion suffisante des éclairs infrarouges invisibles, un
signal est émis par la partie radio. Avec chaque émission, l'état de ten-
sion de la pile est également transmis. Indépendamment d'un signal
de l'état de commutation, il est possible de transmettre régulièrement
un signal d'état qui transmet l'état de commutation actuel du capteur.
Le récepteur doit prendre en charge le protocole sWave® des
modules steute.
Material No.
1202806
Signal d'état
1351045
Un signal d'état peut être réglé par l'utilisateur dans des intervalles
différents par un cavalier. Pour cela, il faut dévisser les 5 vis du cou-
vercle du boîtier avec un tournevis Torx 8. Assurez-vous d'avoir une
protection suffisante contre les décharges électrostatiques (DES).