Télécharger Imprimer la page

Kessel EasyClean free Mix Mode D'emploi page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
4.3
Installing the pipes
Connect the inlet and outlet
Connection of inlet and outlet to the draining system on
site.
If the connections are to be mutually swapped, remove
them together with the screws (1) and seals (2) and
swap them accordingly. Make sure that the seals (3)
have been sufficiently lubricated.
Connecting the riser pipe/disposal pipe
Undo the pipe clamps at the end of the direct disposal
pipe.
Connect the riser pipe (HDPE) provided by the customer
to the direct disposal pipe.
Attachment of the refill inlet
Pull clips off the attachment clamp.
Pull the refill inlet pipe out of the attachment clamp.
Insert the refill inlet pipe with pre-assembled seal into the
opening for pipe penetration.
Slide in the refill inlet pipe in such a way that it can be
fixed in place with the attachment clamp.
Attach clips to the attachment clamp.
Refill inlet is ready for operation.
The supply pipe to the refill inlet must be routed in such a
way that dormant lines are avoided. The risk of contami-
nating the lines with legionella should be excluded as far
as possible.
016-187_02
1
2
3
DA 75
2
1
3
27 / 116