Technical data
Acctiva
Mains voltage
Professional
Nominal output max.
Power
Charging voltage
Charging current I
Boost mode charging current t
Nominal charging capacity
Number of cells
Charging characteristic
Operating temperature *
Storage temperature
Interface
Climate class (EN50178)
EMC Class
Protection
Marks of conformity
Weight inclusive of mains and charger leads
Dimensions w x h x d
*
(adjustable)
2
If the ambient temperature rises to above 35°C (95°F) or thereabouts (depending on
secondary voltage), the secondary output current is reduced (power derating)
(tI
= 30 s, tI
= 60 s)
2 max
2 max
2
IEC/EN 61000-6-4/2 (EMC class A)
30
230-240 V AC, 50/60 Hz
1080 W
12 V
2 - 50 A
max. 70 A
10 - 250 Ah
6
IUoU / IUa / IU
0°C to +60°C
32°F to 140°F
-20°C to +80°C
4°F to 176°F
USB
B
IP 21
see charger rating plate
6.5 kg
14.33 lb.
315 x 200 x 110 mm
12.40 x 7.87 x 4.33 in.