2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash
twice to confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new
codes as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 2 to OFF.
6 - You have completed the procedure.
HOW TO CHECK If THE MEMOrY Is fULL fOr rADIO CODEs UsED ONLY
fOr COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (64 codes have been
stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that
you can delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 2 to OFF.
5 - You have completed the procedure
POINT H
- PrOGrAMMING rADIO CODEs fOr PEDEsTrIAN
OPENING
(UP TO 62 CODEs - ONLY fOr CrX MODELs)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press the remote control button (normally channel B) within the 10 seconds
proscribed. If the remote control has been correctly programmed, the DL2 LED
(green) will flash once.
4 - The code programming time resets automatically so that you can programme
the next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button
briefly. The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 3 to OFF.
N.B: If THE DL1 LED CONTINUEs TO fLAsH rAPIDLY, THIs MEANs
THAT DIP 1 Is sTILL POsITIONED TO ON AND ANY MANOEUVrE HAs
BEEN DELETED.
7 - You have completed the procedure.
PrOCEDUrE fOr DELETING ALL rADIO CODEs UsED ONLY fOr
COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash
twice to confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new
codes as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 3 to OFF.
6 - You have completed the procedure.
HOW TO CHECK If THE MEMOrY Is fULL fOr rADIO CODEs UsED ONLY
fOr COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (64 codes have been
stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that
you can delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 3 to OFF.
5 - You have completed the procedure.
f
UNCTIONING Of CONTrOL ACCEssOrIEs
ATTENTION: ONLY IMPULsIVE COMMANDs HAVE TO BE CONNECTED.
Make sure that any other type of command accessories (e.g. mass
detectors) used on the installation are set in the IMPULsIVE mode,
otherwise, the gate will be operated even without the protection of the
safety devices.
sTEP BY sTEP or AUTOMATIC commands
(K BUTT button, PED BUTT button, RADIO REMOTE button)
DIP 6 - Off The K BUTT, the PED BUTT button, the RADIO REMOTE buttons
perform the cyclic command open-stop-close-open-stop-etc.
DIP 6 - ON
The K BUTT, the PED BUTT button, the RADIO REMOTE buttons
perform:
- the open command, if pressed with the gate completely closed
- the close command, if pressed with the gate completely opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
The K BUTT opens the gate completely, whereas the PED BUTT opens the gate
partially as described in Point F.
CLOCK fUNCTION
If you want the Clock function must request T2 with firmware 08.
ATTENTION: A CLOCK CONNECTED TO T2 with fw 09 or more ACTIVATEs
THE AUTOMATIC MOVEMENT Of THE GATE WITHOUT HAVING THE
PrOTECTION Of THE sAfETY DEVICEs!
The Clock Function is useful during rush hours, when traffic is heavy and the
flow is slow (e.g. entrance/exit of employees, emergencies in residential areas or
car parks and, temporarily, for removal vans) and it's necessary to keep the gate
opened.
CLOCK fUNCTION APPLICATION
It is necessary to request a T2 control panel with firmware 08.
Select the automatic functioning DIP 6 Off.
It can be done by connecting a switch and/or a daily/weekly clock either in parallel
to the K BUTT button or instead of the K BUTT button. When the control board
receives this command, the gate will open and by keeping this contact closed for all
the time of the gate opening, the Clock Function is automatically activated. In fact,
once reached the open position, the gate will remain opened and all of the control
board functions are blocked. Only when K BUTT contact is released, the control
board functions are re-activated and the Automatic Closing restarts (if enabled)
doing the countdown to the gate closing.
PEDEsTrIAN command (PED BUTT - COM)
This command is useful to open the gate partially, just enough, for example, to
permit a pedestrian crossing. In fact, the Pedestrian command (see Point F) is
carried out only by opening the motor M1 just enough for a pedestrian to pass, as
described into the Point F procedure.
From the Pedestrian opening position the Automatic Closing can be enabled or
disabled with DIP3.
From the Pedestrian opening position, the gate can be completely opened by the
OPEN or by the K BUTT button or by the RADIO button.
AUTOMATIC CLOsING (from the COMPLETE open position)
The Automatic Closing from the complete open position can be enabled turning ON
the DIP3.
The maximum gap of time that can be programmed is 5 minutes (see Point D and E).
AUTOMATIC CLOsING (from the PEDEsTrIAN open position)
The Automatic Closing from the pedestrian open position can be enabled turning
ON the DIP3. The maximum gap of time that can be programmed is 5 minutes
(see Point F).
ELECTrIC LOCK (LOCK A+) command
The DIP 8 in the ON position enables the Electric Lock (MAX 15W 12V) command.
The Electric Lock (LOCK A+) will be automatically turned ON each time the gate
opens. If the DIP8 is OFF, the Electric Lock command is DISABLED.
The Electric Lock remains active for 1,5 seconds.
MANUAL rELEAsE fACILITY
The DIP 9 in the ON position enables the Manual Release Facility. Once the gate
has completely closed, a short reversal manoeuvre (0.2 seconds) will be done to
ease manual release.
ELECTrIC LOCK unlocking fACILITY
The DIP 9 in the ON position enables the Electric Lock unlocking Facility. From
32