G
B
R=2,2KΩ
AUTOTEST EDGE
ACCESSORY SUPPLY
POINT B
- sETTINGs
DIP 1
(ON) MOTOr rOTATION DIrECTION CHECK (see Point C)
DIP 2
(ON) PrOGrAMMING (see Point D)
DIP 1-2
STORAGE/DELETION OF RADIO CODES FOR
COMPLETE OPENING (DIP 1 ON followed by DIP 2
ON) (POINT G) ONLY FOR CRX MODELS
DIP 1-3
STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN
OPENING (DIP 1 ON followed by DIP 3 ON) (POINT H) ONLY FOR
CRX MODELS
DIP 2-1
PrOGrAMMING Of THE PEDEsTrIAN OPENING (see Point f)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
OFF - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
ON - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - low speed in approaching ENABLED
OFF - low speed in approaching DISABLED
DIP 8
ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9
ON - Hammering on complete close position to ease Manual Release
- Hammering before opening to ease electric lock unlocking
AERIAL
COAX
SIGNAL
BUZZER
+
-
Vdc for 12
+
-
Vdc for 12
+
-
PHOTOCELL
EDGE
+
PED. BUTTON
COM
ELECTRIC
LOCK
POWER SUPPLY
OFF - no impulse
DIP 10
ON - Extra thrust when reached closing position to make sure that the
mechanical bolt is fixed into the ground
OFF - no impulse
DIP 11
ON - black out function ENABLED
OFF - black out function DISABLED
DIP 12
ON - close command after the transit through the photocell ENABLED
OFF - close command after the transit through the photocell DISABLED
DIP 13
ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 14
OFF for KING 230/50 - 220/60
DIP 15
OFF for KING 230/50 - 220/60
DIP 16
OFF for KING 230/50 - 220/60
JP 17 OPEN JUMPER 1 motor (M1) - 1 leaf
CLOSE JUMPER 2 motors (M1 and M2) - 2 leaves
JP1 => Pay attention that the jumper is inserted!
JP2 => Pay attention that the jumper is inserted!
JP3 => Pay attention that the jumper is inserted!
TOrQUE Tr1 Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies
the output voltage to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 seconds form any manoeuvre begging,
whereas the motor is turned on at full power to guarantee the starting at the
manoeuvre begging.
PAY ATTENTION: If THE TOrQUE TrIMMEr sETTING Is CHANGED, IT Is
PrEfErABLE TO rEPEAT THE TIME PrOGrAMMING.
LOW sPEED Tr2 Electronic regulator for low speed on approach
Adjustment of low speed is carried out using the LOW SPEED Trimmer which
varies the output voltage to the head/s of the motor/s (turn clockwise to increase
speed). Adjustment is carried out to establish the correct speed at the completion
30
30
BLINKER
CAPACITOR M2
MOTOR 2
CAPACITOR M1
MOTOR 1
ON for KING 120/60
OFF for KING 120/60
ON for KING 120/60