of opening and closing, depending on the structure of the gate, or if there is any
light friction that could compromise the correct working of the system. The low
speed is activated (DIP7 OFF) when the gate leaf is 0.50-0.60 meters away from
the complete close or open position.
ATTENTION: WHEN UsING HYDrAULIC OPErATOrs
When using the hydraulic operators the deceleration phase may not operate
correctly; in that case it is advisable to disable the feature of the deceleration
by putting DIP 7 in the Off mode.
LED WArNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (only for CRX)
DL3 - gate opening M2 (green)
DL4 - gate closing M2 (red)
DL5 - gate opening M1 (green)
DL6 - gate closing M1 (red)
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
fUsEs
F1 T100mA
Accessories protection fuse
F2 5A
Motor protection fuse
POINT C
- MOTOr rOTATION DIrECTION CHECK
1 - Unlock the operators with the Manual Release - swing open the leaves about
halfway and lock again the operators.
2 - Turn DIP1 to ON position The red LED DL1 starts blinking.
3 - Press the PROG button and hold it - When GREEN LEDS DL3 and DL5 are
on, the gate leaves are opening (with a phase shift of 2 seconds). Check the
leaves swinging and the opening mechanical stopper position (movement is
now performed in "man present" mode, open-close-open-etc.).
If any of the leaf closes instead of opening, release PROG button, turn off the
main power and reverse the two phase wires (V1/2 and W1/2) of the relevant
motor/s.
4 - Press the PROG button and hold it to CLOSE completely the gate. When RED
LEDS DL4 and DL6 are on, the gate leaves are closing (with a phase shift of 4
seconds). Check leaves swinging and the closing mechanical stopper position.
5 - After 3 seconds motor starting and for the next 10 seconds motor working, the
torque controls automatically activated. Set the motor torque by the TORQUE
Trimmer/s which varies the output voltage to the motor/s (turn clockwise to
increase the torque).
6 - After other 10 seconds motor working, the low speed controls automatically
activated (DIP7 ON). Set the motor low speed by the LOW SPEED Trimmer to
select the gate leaf low speed in approaching.
7 - Close completely the gate.
8 - Turn DIP1 to OFF position, LED DL1 turns off.
During Point C procedure, safety devices (photocells and safetystrip) are not
active and the remote control cannot operate.
(#) In Point D, Point E and Point F procedures, all the safety devices (photocells
and safety strip) will be active, so they must be properly installed and connected
to the control board. Any changing of the safety devices input state, will stop the
Point D, Point E or Point F procedure that must be repeated from the beginning.
POINT D
- PrOGrAMMING fOr 2 MOTOrs (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PrOG. Button, motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the PrOG
button to cut out motor M1 (time travel of M1 has now been just stored with
this operation).
5 - Motor M2 opens, automatically.
6 - Once reached the open position, let 1 second pass and press the PrOG
button to cut out motor M2 (time travel of M2 has now been just stored with
this operation).The gap of time between now (stop of motor M2) and the next
pressing of the PROG. button (see step 7 below) will be then stored as waiting
time for Automatic Closing feature.
7 - Press PrOG. button, M2 closes and the Automatic Closing time is stored (see
DIP3 function to enable or disable the Automatic Closing feature). The gap of
time between now (close of motor M2) and the next pressing of the PROG.
button (see step 8 below) will be stored as time delay between motor M2 and
motor M1 closing, during normal operations.
8 - Press the PrOG. button, motor M1 closes thus setting the delay time between
M2 and M1, as explained in step 7 above.
9 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching
total closing at low speed (depending on the adjustment of LOW SPEED
trimmer).
10 - Turn DIP2 to Off position.
During Point D procedure, the safety devices (photocells and safety strip) are
active.
POINT E
- PrOGrAMMING fOr 1 MOTOr (M1) (#)
ATTENTION: in order to manage one motor only, OPEN JUMPEr JP17.
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking
3 - Press PrOG. button, the motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the PrOG
button to cut out motor M1 (time travel of M1 has now been just stored with
this operation). The gap of time between now (stop of motor M1) and the next
pressing of the PROG. button (see step 5 below) will be then stored as waiting
time for Automatic Closing feature.
5 - Press PrOG. button, M1 closes and the Automatic Closing time is stored (see
DIP3 function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, indicating exit from the Point E procedure. Closing
of the gate will be carried out at normal speed and only on approaching total
closing at low speed (depending on the adjustment of LOW SPEED trimmer).
7 - Turn DIP2 to Off position.
During Point E procedure, the safety devices (photocells and safety strip) are
active.
POINT f
- PrOGrAMMING Of PEDEsTrIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly.
4 - Press the pedestrian pushbutton PED. BUTT, motor M1 opens
5 - When the motor M1 leaf is opened enough for the pedestrian crossing, press
the pedestrian pushbutton to stop the travel (thus defining the opening stroke
of motor M1). The gap of time between now (stop of motor M1) and the next
pressing of the PROG. button (see point 6 below) will be stored as waiting time
for Pedestrian Automatic Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, M1 closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the
Automatic Closing feature).
7 - Turn DIP1 to Off position.
8 - Turn DIP2 to Off position.
During Point F procedure, the safety devices (photocells and safety strip) are
active.
POINT G
- PrOGrAMMING rADIO CODEs fOr COMPLETE
OPENING
(UP TO 62 CODEs - ONLY fOr CrX MODELs)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each,
for 10 seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds
proscribed. If the remote control has been correctly programmed, the DL2 LED
(green) will flash once.
4 - The code programming time resets automatically so that you can programme
the next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button
briefly. The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PrOCEDUrE fOr DELETING ALL rADIO CODEs UsED ONLY fOr
COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
31