Suction Lift; Mechanical Installation; Location; Foundation - Grundfos MQ Serie Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.1 Suction lift

The maximum suction lift of the pump can be
determined from the diagram, page 49.
Example:
If the suction lift is 10 ft, the length of the suction pipe
must not exceed 72 ft.

7. Mechanical installation

7.1 Location

The pump is suitable for indoor and outdoor
installation. It is resistant to sunlight.
For outdoor installation, the pump must
be fitted with a protective cover
Note
(accessory). See section 7.5 Protective
cover and 13. Accessories.
Should the unlikely event of an internal
leakage occur, pumped liquid will be
drained out from the base and/or end
cover instead of damaging the pump.
Note
Install the pump in such a way that no
undesirable collateral damage can
arise.

7.2 Foundation

Mount the pump on the base plate with horizontal
suction port and vertical discharge port.
The pump must be installed horizontally.
The maximum permissible inclination angle is ± 18 °.
See fig. 2.
Max. ± 18 °
Fig. 2
Horizontal installation of the MQ
To prevent movement and vibrations, the pump and
base plate can be secured to a solid foundation by
means of the bolt holes in the base plate. For
pipework connection, see section 7.4 Pipework.
6

7.3 Space requirement

For inspection and service, allow a minimum
clearance of 60" behind the pump.
Fig. 3
Minimum clearance behind the pump
Being self-cooling, the pump requires no space or
ventilation at the sides.
Ensure that the maximum ambient
temperatures do not exceed the values
Note
stated in section 6. Operating
conditions.

7.4 Pipework

Never use unnecessary force when
Note
connecting the pipes.
The pump is supplied with 1" NPT screwed
connections. Fit the connections in the suction and
discharge ports. See fig. 4. The pump discharge port
is flexible, ± 5 °, to facilitate the fitting.
Fig. 4
Fitting of screwed connections in suction
and discharge ports
Carefully screw the discharge connection into the
discharge port, using a spanner or similar tool.
Hold the discharge connection, and tighten the pump
discharge union nut with your hand. See fig. 5.
Fig. 5
Correct: Tighten the discharge union nut
with your hand
60"