Télécharger Imprimer la page

Kospel SW Instructions D'installation Et D'utilisation page 22

Publicité

Les langues disponibles

Les langues disponibles

Assembly and operating instructions
1.
Read and strictly follow this assembly and operating instructions to ensure
a long life and reliable cylinder operation.
2.
The manufacturer of this cylinder will not be liable for any damages due to the failure
to follow the assembly and operation instructions.
3.
The cylinder must not be installed in rooms where the temperature may drop below
0°C.
4.
The cylinder installation and initial start-up as well as all electrical and hydraulic work
must be performed by a qualified professional installer and strictly follow installation
and product instructions.
5.
The cylinder is designed for vertical installation only (screw on feet).
6.
The cylinder must be mounted in the place and in such a way to avoid room flooding
caused be leaking tank or connectors.
7.
Connections with water installation, central heating and solar system pipes must be
made in accordance with diagram in this assembly instruction. Failure to observe
the installation instruction invalidate the warranty and may cause cylinder damage.
8.
A connection with water installation must be made in accordance with the legally
binding standards.
9.
The cylinder is a pressure appliance designed for connection with water installation
where the water pressure doesn't exceed 0,6 MPa. If the water pressure exceeds
0,6 MPa the pressure reducing valve before cylinder must be fitted.
10. A small leak from the safety valve through the outlet pipe may occur, it is a normal
operating state of the appliance. The outlet of the pipe has to remain opened.
Do not clog it, as a clogged outlet may cause a break down of the cylinder.
11. Do not use the cylinder if you suspect that the safety valve may be faulty.
12. The storage is equipped with a magnesium anode - an additional protection against
corrosion. The anode is an operating part therefore it is exposed to wear.
The condition of the magnesium anode should be controlled every 12 months.
The anode must be replaced once every 18 months.
13. Rated temperature of water in the cylinder should not exceed 95°C and in the case
of exchangers with capacities of 250; 300; 400 i 500L - 80°C!
The cylinder is suitable for fitting an immersion heater with thermostat e.g. GRW 1.4,
GRW 2.0. The immersion heater must be fitted in cork 1½".
A maximum length of immersion heater:
-
360 mm (Cylinders of 100,120,140 litres),
-
450 mm (Cylinders of 200 litres),
-
550 mm (Cylinders of 250,300 litres),
-
600 mm (Cylinders of 400 litres),
-
670 mm (Cylinders of 500-1000 litres).
22

Publicité

loading