7.4.3 Default values

If it is necessary to restore the camera's default
configuration (factory settings), click on the Setup
key and then press Factory Defaults and Save
Settings...
Fig. 19
For the full description of all the advanced options of
the Camera Controller GUI software, refer to the FLIR
Camera Controller GUI User's Guide.

8 Maintaining and cleaning

8.1 Maintaining

8.1.1 Replacement of the germanium
glass
Unscrew the fixing screws of the front flange using
the supplied Allen wrench. Remove the flange and
position the spare part, making sure the gasket
remains in place. Tighten the 4 fixing screws.
Fig. 20

8.1.2 Fuses replacement

Use a fuse with the following features:
T 500mA L 250V