2. PREPARE THE INSTALLATION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
Tools needed to install the range hood:
- Phillips screwdriver no. 2
- Pair of long nose pliers
- Flat blade screwdriver (to open the electrical knockout hole)
- Scissors (to cut metal foil duct tape)
- Wire stripper
Make sure the following items are included:
- Hood
- Adapter/dampers: Horizontal 3¼" x 10", vertical 3¼" x 10" and vertical 6" round
- Halogen bulbs (2) (JC type, 12 V, 20 W, G-4 base)
- Parts bag including:
1 wire clamp, 4 no. ST4.8 x 15 mm mounting screws, 3 wire connectors
NOTE: If the bottom of the cabinet is recessed, attach wood strips (not included), as shown
beside, in order to properly install the range hood under the cabinet. The wood strips
must be as thick as recess.
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See illustrations
below.
V
ERTICAL DISCHARGE
C L
6" DIA.
B
12
5
⁄
"
8
1¼"
C
ABINET BOTTOM VIEW
HD0410A
V
ERTICAL DISCHARGE
C L
3½"
B
12
5
⁄
"
8
1¼"
C
ABINET BOTTOM VIEW
HD0411A
(6"
)
ROUND DUCT
A
5"
(3¼"
10"
)
X
DUCT
10½"
A
1¾"
!
WARNING
-4-
HO0153
H
ORIZONTAL DISCHARGE
A
3¼"
1"
12"
C L
12
B
C
ABINET BOTTOM VIEW
HD0337A
5
⁄
"
8