2. MEASURE INSTALLATION

Dimensions for the most common installation are shown below.
The minimum hood distance above cooktop must not be less than 24''. A maximum of 30" above cooktop is
highly recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
S tandard 18"
18"
(457 mm ) H
(457 mm)
over - cooktop
19"
cabinet
(483 mm)
Hood
24"
(610 mm)
Standard 36"
(914 mm)
Cooktop
H cooktop
INSTALLATION WITH STANDARD 18''
HIGH OVER-COOKTOP CABINET

3. PREPARE THE INSTALLATION

Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Wood strip
- Installation manual
- Accessories including:
• Filters (Quantity varies depending on range hood width)
• Bag of parts including:
(4) flat head screws no. 10-2'', (8) screws no. 8 x 3/4'', (4) nuts no. 10-32, (2) wall anchors, (2) washers 3/16'' ID x 3/4'' OD
Parts sold separately:
- Interior blower Model RM325H or RM326H (both include rough-in kit)
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers
- Exterior blower assembly 331H, 332H, 335 or 336
- Halogen lights (120 V, 50 W, PAR 20)
- Heat lamps (Infrared, 120 V, BR40, 250 W max.)
- RMP Series Backsplash (optional)
- RBF Series Baffle filters (optional)
- Transitions, duct, elbows, dampers, wall and roof caps.
Refer to pages 4 and 5 for a complete list of venting options
and model numbers.
Using a Phillips no. 2 or a Robertson no. 2 screwdriver, unscrew the
hood from the bottom of crate. Refer to figure beside to locate all 4
screws. Discard these screws and remove hood from wood pallet.
All manuals and user guides at all-guides.com
Standard
8 ft. (2.44 m)
ceiling
Top of wood
mounting strip
RMP Series
Backsplash
(optional)
HH0028A
INSTALLATION WITH STANDARD
12'' SOFFIT OR OPTIONAL
SOFFIT CHIMNEY RMN SERIES
3
1
HR0002
- 7 -
4
2

Publicité

Table des Matières
loading

Table des Matières