1. INSTALL DUCTWORK

Choose where the ductwork will run between the hood and the outside.
A straight, short duct run will allow the hood to perform most efficiently.
Long duct runs and elbows will reduce the performance of the hood. Use as few of them as possible.
Install proper-sized ductwork, elbow(s) and roof or wall cap for the type of discharge chosen. Use 2'' metal foil duct tape to seal joints.
VERTICAL DISCHARGE
USING 6" ROUND DUCT
R
OOF CAP
A
DJUSTABLE
ELBOW
A
/
DAPTER
DAMPER
26"
MINIMUM ABOVE
COOKING SURFACE
(28"
)
FOR GAS RANGE
HH0144A
NOTE: We recommend to install the hood at a minimum of 26" from an electric range and at 28" from a gas range. For optimal
performance, the hood should not be installed more than 30" from cooking surface.
TABLE OF CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
OOD
H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
OOD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
M
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10
AINTENANCE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
W
ALL CAP
26"
(28"
HH0146A
WARNING
!
CAUTION
VERTICAL DISCHARGE
USING 3¼" X 10" DUCT
R
OOF CAP
A
E
DJUSTABLE
AVES CAP
ELBOW
A
/
DAPTER
W
ALL CAP
DAMPER
MINIMUM ABOVE
COOKING SURFACE
)
FOR GAS RANGE
-3-
HORIZONTAL DISCHARGE
USING 3¼" X 10" DUCT
A
/
W
DAPTER
DAMPER
ALL CAP
26"
MINIMUM ABOVE
COOKING SURFACE
(28"
)
FOR GAS RANGE
HH0145A

Publicité

Chapitres

Table des Matières
loading

Table des Matières