INSTALL THE DUCTWORK
(Ducted Hoods Only)
1. Decide where
the ductwork
will run
between the
hood and the
outside.
2. A straight, short
duct run will
allow the hood
to perform most
efficiently.
3. Long duct
runs, elbows
and transitions
will reduce the
performance of
the hood. Use as few of them as possible. Larger ducting
may be required for best performance with longer duct runs.
4. Install wall cap or roof cap. Connect round metal ductwork
to cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.
MEASURE THE INSTALLATION
6" ROUND DUCT
DECORATIVE FLUE
ROUND ELBOW
HOOD
9-3/4"
30" - 36" ABOVE
COOKING SURFACE
The minimum hood distance above cooktop MUST NOT BE
LESS than 30".
A maximum of 36" above cooktop is highly recommended for
best capture of cooking impurities.
Distances over 36" are at the installer and users discretion;
providing that the ceiling height permits.
All manuals and user guides at all-guides.com
ROOF CAP
6"
ROUND DUCT
DECORATIVE
WALL
FLUE
ROUND
HOOD
ELBOW
24" MIN. ABOVE
COOKING SURFACE
ROOF CAP
WALL CAP
HOOD
MOUNTING
BRACKET
10-5/8"
TO CENTER OF
BRACKET HOLES
3-3/8"
DUCT
CENTER
LINE
PREPARE THE HOOD
Unpack hood and check contents. You should receive:
1 - Hood
1 - Decorative Flue Assembly
1 - Damper / Duct Connector
1 - Lower Flue Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Hood Mounting Bracket
2 - Aluminum Grease Filters (installed in hood)
1 - Installation Manual
CAP
2 - Light Bulbs (packed separately)
1 - Parts Bag containing:
10 - Mounting Screws (#8 x 3/8" Pan Head)
7 - Mounting Screws (#8 x 1-1/2" Flat Head)
7 - Drywall Anchors
2 - Washers
DECORATIVE FLUE
DAMPER /
DUCT
CONNECTOR
BW50 SERIES
2 CANDELABRA
BULBS
10 MOUNTING
7 MOUNTING
SCREWS
(#8 X 1-1/2"
Flat Head)
HOOD
MOUNTING
UPPER
BRACKET
FLUE MOUNTING
BRACKET
LOWER
FLUE MOUNTING
BRACKET
Page 3
SCREWS
(#8 x 3/8"
Pan Head)
2 WASHERS
7 DRYWALL
ANCHORS