Additional safety notices
■
If applicable, observe special work safety or
accident prevention regulations for the handling
of compressors and compressed-air tools.
■
Ensure that the maximum permissible working
pressure specified in the Technical Data is not
exceeded.
■
Do not overload this tool – use this tool only
within the capacity range specified in the
Technical Data.
■
Use safe lubricants. Ensure sufficient ventilation
at the place of work. In case of increased
discharge:
check the compressed-air tool and have it
repaired if necessary.
■
Do not use this tool if you are distracted. Be
alert, watch what you are doing and use com-
mon sense when operating a compressed-air
tool. Do not use tools when you feel tired or are
under influence of drugs, alcohol, or medica-
tion. A moment of inattention when operating
the tool can result in serious personal injuries.
■
Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
■
Keep compressed-air tools out of reach of
children.
■
Do not store outdoors or in damp environments
without protection.
■
Protect the compressed-air tool, in particular
the compressed air connection and operating
elements against dust and dirt.
PDBS 1800 A1
Before use
NOTE
►
The compressed-air tool may only be operat-
ed using cleaned, oil-atomised compressed
air and the maximum operating pressure of
6.8 bar must not be exceeded on the tool.
The compressor must be fitted with a pressure
reducer to regulate the working pressure.
Lubrication
WARNING!
►
Inform yourself about the health hazards of
the oil used in the safety data sheet of the
respective manufacturer.
NOTE
►
Regular lubrication is particularly important to
avoid friction and corrosion damage.
We recommend using a suitable special oil
for compressed-air tools (e.g. Liqui Moly
compressor oil).
–
Lubrication with mist oiler
A mist oiler (not supplied) continuously
and optimally lubricates the grinder as
a preparation stage after the pressure
reducer. A mist oiler gives off fine drops of
oil into the air flow and thus guarantees a
regular lubrication.
–
Manual lubrication
If you do not have a mist oiler, lubricate
the tool before every use or longer work
sessions. Add 3–4 drops of pneumatic oil
into the connector nipple
.
GB │ IE
│
27
■