8843732
Problem(s)
The stroke is too
short.
The riveter has
weak pulling
action.
Leaking air.
14
1/4 in. Air Riveter
Possible Cause(s)
1. The rivet pin is not
properly inserted into
the riveter.
2. The riveter is low on
hydraulic oil.
3. The rivet is the wrong
size
4. Piston stroke is
misadjusted.
1. Low air pressure.
2. Inadequately sized
compressor.
3. Damaged air compressor.
4. The riveter is low on
hydraulic oil.
1. There are poor hose
connections in the
system.
2. Damaged O-ring.
3. Dirty air valve or air
inlet.
Suggested Solution(s)
1. Fully insert the rivet pin.
2. Top up the hydraulic oil
reservoir and prime the
riveter.
3. Use the proper rivet length.
4. Adjust the piston stroke.
1. Check the regulator to verify
that it is set to 90 PSI.
2. Upgrade to a suitable
compressor of adequate
capability.
3. Have the compressor serviced
by a qualified service centre.
4. Top up the hydraulic oil
reservoir and prime the
riveter.
1. Reconnect the air system
using thread sealant tape on
the fittings.
2. Replace the O-ring.
3. Clean and lubricate with
pneumatic tool oil.
For technical questions call 1-800-665-8685