Failures
No.
Fault
The heater does not heat
1.
water and a signal lamp
does not work.
The heater does not heat
2.
water and a signal lamp
works.
The heater heats water
3.
and a signal lamp does
not work.
Technical data
Type
Capacity
Rated power
Rated current
Type
Capacity
Rated power
Rated current
Voltage
Temperature range
Pressure rating
Dimensions (height x
width x depth)
Weight
(without water)
Safety class
Water heater fittings
PL;DE;EN;FR-029B_f.1196
Reason
Supply power system
failure.
A temperature controller
failure.
Heating box failure.
A thermal cut-out
problem
A signal lamp failure
l
W
A
l
W
A
°C
MPa
POC.5
mm
POC.10
POC.5
kg
POC.10
Check safety fuses.
Replace the temperature
controller (service)
Replace the damaged
unit. (service)
Turn on or exchange the
thermal cut-out (service)
Replace the lamp.
(service)
POC.D-5
POC.G-5
2000
8,3 - 9,1
POC.D-10
POC.G-10
2000
8,3 - 9,1
220 - 240V~
23 - 70
427 x 285 x 163
470 x 329 x 239
IP24
G 1/2"
Remedies
POC.D-5/600
5
600
2,5 - 2,7
-
10
-
-
0,6
4,4
6,1
EN
17