Hydraulic connection
POC.G and POC.D as a pressure appliances are designed to work on the system with
water pressure not exceeding 0,6MPa. If the water pressure in the system exceeds
0,6MPa, a pressure reducing valve has to be fitted before the safety valve on the cold
water supply pipe. An occasional leak may appear from the safety valve it does not
mean that there is a fault; it is a normal state of the appliance. You must not block the
pipe as it might cause a malfunction. Safety valve as well as the outlet pipe can not be
installed in a room with temperatures below zero. Between the heater and the safety
valve no cutoff valve can be placed.
The POC.G heater must be mounted
with connections to down
POC.G
Electrical connection
The heater can be supplied with alternating voltage of 230V~. A cord with a plug
should be connected to a plugin socket with a safety pin. Electrical system should fulfil
IEC60364 standards.
Important! Do not connect the heater to the electric mains before the inner tank is
completely filled up with the water.
PL;DE;EN;FR-029B_f.1196
The POC.D heater must be mounted
with connections to the top
POC.D
[3] - inlet fitting
(cold water)
[4] - outlet fitting
(hot water)
[5] - hot water outlet
[6] - safety valve
[7] - pressure reducing
valve (if the water
pressure in the system
exceeds 0,6 MPa)
[8] - cut-off valve
[9] - cold water inlet