KDE3 Operation
The heater switches on automatically straight after reaching the flow rate over 2,5l/min.
The temperature control system adjusts the power rate according to the water flow rate,
required temperature and the water temperature in the mains.
There are two indicators on the case:
-
green - power supply „on",
-
red - heating „on".
Other modes are shown by flickering green light.
Number
of impulses
(green indicator)
1
2
3
4
18
The unit was switched off because the temperature has
exceeded the maximum value (fault signal will not disappear
until the appropriate rate of water flow is reached).
The unit was switched off by a master appliance
The inlet temperature sensor failure
The unit was switched off because the air bubbles in the heating
box (the unit will not heat again until the fault is resolved and
the appropriate rate of flow is reached).