Connecting the electrical brush
For devices with socket:
-
Connect the electrical brush's plug to the
socket (25 Fig.12) located on the top of
the vacuum (maximum output 200 W)
Liquid suction
For appliances equipped with suitable acces-
sories.
-
Release the levers (8 Fig.3) and remove
the cover (9 Fig.4) complete with the mo-
tor unit.
-
Check for a filter in Nylon (46 Fig. 4).
-
Remove the polyester filter (10 Fig.5) if
present.
-
Remove the paper bag (11 Fig.5) if pre-
sent.
-
Place the cover back on and lock it using
the levers (8 Fig.3).
-
Insert, as far as possible, the sleeve (14
Fig.7) of the suction hose into the nozzle
(15 Fig.7) on the drum.
-
To release the sleeve (14 Fig.7) turn the
lever (16 Fig.7) clockwise and then pull
the sleeve outwards (14 Fig.7).
-
Merge the ergonomic handle (17 Fig.8) or
hose (18 Fig.8) depending on the model,
with the extension (19 Fig.8).
-
Connect the two rigid extensions (19-
20 Fig.9) by aligning the two reference
points (21-22 Fig.9).
-
Mount on the rigid extension (20 Fig.10)
the desired accessory,( vacuum nozzle,
floor nozzle etc..)
NOTES:
For models equipped with ergonomic handle
it is possible to adjust the suction force acting
the nut (23 Fig.11).
By opening the little window (24 Fig.11) you
get a lower suction force.
USING THE APPLICANCE
-
The device is equipped with wheels and
thus can be moved with the proper han-
dles, or it can be pushed with the help of
the handle (26 Fig.13)
-
To lift it up insert your fingers under the
dedicated handle (27 Fig.14) on the top
of the cover of the single version motor or
lift with the help of two people using the
handles (28 Fig.13)
Starting up the appliance
-
Insert the plug (29 Fig.15) into the socket.
Single motor
-
Push the switch (30 Fig.16) on "I" to start
the suction motor; the switch lights up.
Double motor
-
Depending on the power required it is
possible to start only one motor by press-
ing the switch (31 Fig.16) on "I" or both
switches (31 e 32 Fig.16) if a greater suc-
tion force is required.
When the switch pressed the correspond-
ing button lights up.
NOTES:
When the recovery tank is full, the noise
intensity increases and the device can no
longer aspire. Then you must switch off the
device and empty the tank as described in
the relevant paragraphs.
Switching off the appliance
-
Push the switches (30, 31, 32 Fig.16) to
the "0" position to stop the device; the
lights, if any on the switches, will go off.
-
Remove the plug (29 Fig.15) from the
electrical socket.
-
Wind up the cable (33 Fig.17) and hook it
onto its housing (34 Fig.17).
ENGLISH - 2