Emergencies - Pit Boss TG2SS Instructions Et Utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.
Perform a leak test and check burner operation after re-assembly.
10. Replace flavor activator and cooking grid.
Problem
Gas leaking from LP
Gas Cylinder.
Gas leaking between
LP Gas Cylinder
and regulator
connection.
Grease fire or
excessive flames
above cooking
surface.
Flashback
(Fire in or
around Venturi tubes).
All manuals and user guides at all-guides.com

EMERGENCIES

Possible Cause
Mechanical failure
due to rust or
mishandling.
Improper installation,
connection not tight,
failure of seal on LP
Gas Cylinder.
To much grease
build-up in burner
section.
Clogged or blocked
Venturi tube.
Solution
Replace LP Gas Cylinder.
Remove LP Gas Cylinder. Re-install
correctly and tighten. Replace
Cylinder if damaged. See "Leak
Test" and "Connecting Regulator
to LP Gas Cylinder" sections.
Turn off Regulator Knob and
remove LP Gas Cylinder. Once
fire is out and grill has cooled off,
clean residual food particles and
excess grease from inside firebox
area, grease cup, and other
surfaces.
If you can safely reach the
Regulator Knob, turn it to the
"Off" position, then remove the
LP Gas Cylinder. Once grill has
cooled, clean burner and Venturi
tubes. See "How to Clean Burners"
section.
22

Publicité

Chapitres

Table des Matières
loading

Table des Matières