spectrum at variable speeds. This function is only available
on units in the FULL COLOUR version.
The control of this function is proportional.
The projection order of the colour macro, which changes in
a fade-in-fade-out sequence (progressive mixing of colours),
corresponds to the following cycle :
YELLOW
RED
MAGENTA
BLUE
The variation speed of the colour macro increases in
accordance with the DMX value sent on the relevant DMX
channel.
The following table indicates the speeds obtained every 5%
of the value of the relevant DMX channel :
COLOUR MACRO
Channel DMX Values
%
0-255
< 3%
0-7
3%
8
5%
13
10%
26
15%
38
20%
51
25%
64
30%
77
35%
89
40%
102
45%
115
50%
128
55%
140
60%
153
65%
166
70%
179
75%
191
80%
204
85%
217
90%
230
93-100%
238-255
''Dimmer'' function
Manages the general intensity of the light emitted by the
device.
The control of this function is proportional.
DMX Value
DIMMER ''INVERTED''
0%
From 0% to 100%
Proportional Closing
Variation
100%
CLOSED
GREEN
CYAN
COLOUR MACRO SPEED
OFF
37 min
35 min 51 sec
32 min 53 sec
30 min 9 sec
27 min 11 sec
24 min 13 sec
21 min 15 sec
18 min 31 sec
15 min 33 sec
12 min 36 sec
9 min 38 sec
6 min 54 sec
3 min 56 sec
1 min 8 sec
32 sec
13,7 sec
9 sec
5 sec
2,88 sec
2,16 sec
DIMMER ''NORMAL''
OPEN
CLOSED
Proportional Opening
OPEN
USER MANUAL
The dimmer can be parameterised with the use of an DMX
RDM controller.
''Colour temperature'' function
Function allowing the COLOUR temperature (°K) to be varied
proportionally on a single channel of the light emitted by the
unit, from the lowest to the highest colour temperature.
This function is only available on CTC-version units.
DMX channel at 0: WARM WHITE (2700°K)
DMX channel at 50%: WARM WHITE + COLD WHITE
DMX channel at 100%: COLD WHITE (7000°K)
The colour temperature of the light emitted by the projector
increases with the DMX value sent on the relevant DMX
channel.

Control

The ARCALINE2 3G is designed to be controlled by a signal
in compliance with the USITT DMX512 protocol only.
Light consoles or other computer interfaces delivering
this type of control signal can therefore be used with the
ARCALINE2 3G.
The parameterisation of the DMX address, the DMX operating
mode and a number of the ARCALINE2 3G options, requires
the use of a DMX controller supporting the RDM standard.
This luminaire does not have Stand Alone mode.

Adjustable parameters

The following parameters can be consulted and adjusted
by means of a DMX controller that complies with the RDM
(Remote Device Management) standard :
DMX ADRESS
Choice of address of the unit's first control channel
DMX MODE
Choice of the number of DMX channels required to run
the unit
LUMINOSITY MODE
Choice of "ENTERTAINMENT" or "ARCHITECTURAL"
mode
The "Entertainment" mode enables you to get the very
best out of the unit's power capacity, depending on
13