harming deformation.
The installation must always be secured with a secondary safety
attachment, e.g. an appropriate safety rope.
Never stand directly below the device when mounting, removing
or servicing the fixture.
The operator has to make sure the safety relating and machine
technical installations are approved by an expert before taking
the device into operation for the first time.
These installations have to be approved by a skilled person once
a year.
CAUTION !
Before taking into operation for the first time, the
installation has to be approved by an expert.
Cautions :
The effect should be installed outside areas where persons may
reach it, walk by or be seated.
Overhead mounting requires extensive experience, including
amongst others calculating working load limits, installation material
being used, and periodic safety inspection of all installation
material and the device. If you lack these qualifications, do not
attempt the installation yourself. Improper installation can result
in bodily injury.
CAUTION !
The electric connection must only be carried
out by a qualified electrician.
Before mounting make sure that the installation area can hold a
minimum point load of 10 times the device's weight.
Connect the fixture to the mains with the power plug.
Installation method via clamp
Please refer to the picture below:
Fix the clamp on the bracket by tighten up the M12 screw on the
bracket to the 13mm hole in the middle of the bracket. Pass the
safety rope through the connecting hole under the side panel,
hanging on the fixed bracket or other fixed station, and can also
be floor-mounted (or on any other flat surface) without fixing,
remaining steady no matter what the angle of the head. Fully
operational in any mounting position, hanging upside-down,
side mounted, or set on a flat level surface, etc. When clamp
mounting; always use and install the supplied safety cable as
an added safety measure to prevent accidental damage in the
event of a clamp failure. Be sure this fixture is kept at least 0.1m
away from any flammable materials (decoration etc.).
DMX-512 control connection
Connect the provided XLR cable to the female 5-pin XLR output
of your controller and the other side to the male 5-pin XLR input
of the moving head. You can chain multiple
Moving head together through serial linking. The cable needed
should be two core, screened cable with XLR input and output
connectors. Please refer to the diagram below.
DMX Output
5-Pin XLR Socket
5
1
4
2
3
Address 1
DMX-512 connection with DMX
terminator
For installations where the DMX cable has to run a long
distance or is in an electrically noisy environment, such as in
a discotheque, it is recommended to use a DMX terminator.
This helps in preventing corruption of the digital control signal by
electrical noise. The DMX terminator is simply an XLR plug with
a 120 Ohms resistor connected between pins 2 and 3, which is
then plugged into the output XLR socket of the last fixture in the
chain. Please see illustrations below.
USER MANUAL
6
DMX Input
5-Pin XLR Socket
1. Ground
1
5
2. Signal (-)
3. Signal (+)
2
4
3
4. N.A.
5. N.A.
Address 9
Address 17
4
5