Technical Parameters - STAMOS S-MMA-160-I Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19

TECHNICAL PARAMETERS:

Parameters
S-MMA-160-I S-MMA-200-I-Mini S-MMA-250-I
Voltage supply V
Frequency (Hz)
Rated input current (A)
19.7
No-load voltage (V)
56
Output current (A)
20-160
Rated output voltage (V)
26.4
Duty cycle (%)
80
Current (A) at Duty cycle 100%
135
No-load loss (W)
40
Efficiency
80
Power factor
0.73
Insulation grade
H
Housing protection grade
IP21
START - UP
A. Unpacking
Unpack all items from the package and ensure that all items, specified within the scope
of the delivery are present.
B. Work environment
It is necessary to ensure well ventilation within the working area. The device is cooled
by the fan which ensures cooling for all internal subassemblies of the device. (Tip! The
guards must be installed in such way that the vent holes could be located at the front
side of the device) In order to leave some space for cleaning and cooling, the device
should be located within the distance of at least 15 cm (from each side) from other
objects. If the device is not efficiently cooled, the make-time decreases.
C. Conduits connection
Each device is equipped with feeder cable which supplies it with electric voltage. If the
device is connected to the current source with the voltage exceeding supply rated
voltage or improper phase is connect, it may result in serious damage of the machine.
The device which has been damages in such course does not subject to repair under
the warranty terms.
EN
Model
1phase AC 230V
50
24
32
56
56
20-200
20-250
28
30
60
60
155
194
40
60
85
85
0.93
0.93
F
F
IP21
IP21
22
Rev. 17.03.2017
INSTRUCTION OF OPERATION
Manual welding with the electrode
Connect the E-Hand conduit to the negative pole (-).
Set the current intensity regulator at the proper intensity (the impulse current
intensity regulator is in lower position). Select current in accordance with empirical
formula: I=40d, where d is the electrode diameter.
Positive and negative connection during the welding process.
The welder has to be connected to the electric supply socket and turn main switch
on. The control lamp will light.
It is necessary to bring the attention to the relative intensity of welding current and
the relative welder's make-time.
The overloading may result in damages. You can avoid this.
After finishing the device operation, it is necessary to leave the device for cooling
and then – switch off the supply.
MAINTENANCE
Check if the room ventilation works properly.
TROUBLESHOOTING
Problem
Electric source indicator doesn't light.
Fan doesn't run. No welding output
Electric source indicator lights but the
fan doesn't run or stop for a while. No
welding output.
Fan is running but output current is
unstable or cannot been controlled by
potentiometer.
Fan runs but abnormal indicator doesn't
light. No welding output.
The abnormal indicator lights and fan
runs but no welding output.
Rev. 17.03.2017
EN
Troubleshooting
1. Check power switch.
2. Check input wires.
1. Connect with wrong electric source.
Change the connection into single 220V.
2. 220V power system is unstable.
3. Power off or power on continuously
in a short time and cause the over-volta-
ge protection.
4. Wire which connects switch and elec-
trical source is loose. Fix it again.
1. Potentiometer (1K) is bad;
2. Some connecting terminals aren't
fixed well.
1. Check all plug-ins are in good connec-
tion.
2. If the output terminals is in opening
or loose connection.
1. Over-current protected. Power off
firstly and power on again.
2. Over-heat protected. I will get normal
after waiting for 2 minutes to 3 minutes
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S-mma-200-i-miniS-mma-250-i

Table des Matières