Cleaning Metal Grease Filters; Replacing Activated Charcoal Filter - Faber Inca Lux 21 SS Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleaning metal grease filters
The metal grease filters can be cleaned in hot detergent solution or
washed in the dishwasher. They should be cleaned every 2 months
• Remove grease filters.
use, or more frequently if use is particularly heavy.
• Open the Panel by pulling it.
• Remove the filter, pushing the lever towards the back of the unit and
at the same time pulling downward.
• Wash the filter without bending it, leave it to dry thoroughly before
replacing (if the surface of the filter changes color over time, this will
have absolutely no effect on its efficiency).
• Replace, taking care to ensure that the handle faces forward.
• Screw the Frame into place
• Cleaning in dishwasher may dull the finish of the metal grease
filter.
• Close the Panel.

Replacing Activated Charcoal Filter

The Activated Charcoal Filters are not washable and cannot
be regenerated, and must be replaced approximately every 4
months of operation, or more frequently with heavy usage.
• Open the Panel by pulling it.
• Remove the Filter, pushing it towards the back of the unit and at the same
time pulling downward.
• Remove the saturated Activated Charcoal Filters, as indicated (A).
• Fit the new Filters, as indicated (B).
EN
• Replace, taking care to ensure that the handle faces forwards.
• Close the Panel.
Replacing the two 35W Halogen GU10 bulbs
• Turn off electrical supply before replacing bulbs, and
make sure bulbs are cool to touch before proceeding.
• Carefully remove the snap-on lamp cover using a flat
head screwdriver by levering it down from under the
metal ring.
• After the snap-on lamp cover is down remove the
halogen lamp at the base and turn slightly to the left
and the pull out from the connector and turn slightly
to the left.
• Replace the lamp with a new one of the same type,
making sure that you insert the two pins properly into
the housings on the lamp holder.
• Replace the snap-on lamp cover.
• Once the bulb pins are in place turn slightly to the right
to secure.
fixing pin lever.
using the 6 screws 12f, re-
connect the wires to the
Commands and Light, re-
place the metal grease filter
and the Panel.