SEASONAL WORK
When the unit is kept unused for a long time, please take note of the following procedures:
- unplug the unit;
- clean and dry well the tank;
- leave the door open to avoid possible formation of bad smells;
- cover the unit with a curtain, place it in a dry room and sheltered from the atmospheric agents.

CONDENSER CLEANING

At least once every 12 months remove from the condenser unit ventilated (AB700 / EC-EF) or static
(AB400/AB500) the impurity (dust and deposit) which remain among the fins of the condenser,
obstructing a good circulation of the air .A dirty condenser reduces the performance of the equipment,
increasing the energy consumption. Cleaning should be carried out with a soft brush or preferably with
a vacuum cleaner. The manufacturer recommends that this operation be carried out only by an
Authorized Technician.

MALFUNCTIONS AND REMEDIES

Most of the functioning inconveniences are generally due to simple causes or to defective electrical
connections. These problems can usually be solved on the place .
The unit does not start:
- check that there is voltage at the wall socket;
- check that the unit is properly plugged.
The internal temperature is not cold enough:
- check that the unit is not placed too close to any heating source;
- check that there is not too much ice on tank walls;
- check the temperature setting ;
- check that behind the cabinet air can properly circulate;
The unit is noisy:
- check that all the bolts and nuts are properly fasten;
- check that the unit is placed on an even surface;
- check if any pipe or fan is in contact with any other part of the body.
INFORMATIONS ABOUT SERVICE