4. Assembly

The following tools are necessary:
4mm and 5 mm Allen Key
6mm, 10mm and 13 mm Wrench

Operation

FIG 3:
Screws for adjusting the levelling of the stove.
FIG 4:
Set magnets FIG 4A in vertical position
so than intended gap between the top plate
and the door = 4mm - see FIG 4B.
When final position is set remove silicone
pads FIG 4C and assemble the top FIG 4D.
FIG 5: The Thermotte elements
FIG 11: The air vent control is adjusted with the lever
placed on the left side of the stove

Operating control

When the stove is in position, check that all functions
are easy to manoeuvre and appear satisfactory.
Door
Handle turned outwards
Handle parallel with door
frame
Air vent control (FIG 11)
Forward
Back
Removal of self closing mechanism FIG 18
A. Open the door and tighten the set screw using a
2,5 mm Allen Key.
B. Carefully push the door upwards
Loosen the set screw with the Allen key.
C. The door can now be lowered back into place.
Attention! In some countries removing the self
closing mechanism is not allowed. Make sure you
follow the local rules and regulations regarding self
closing doors.

Flue outlet collar

Quadro is delivered as standard with a top flue outlet
collar. In order to utilize top chimney conncection you
need to:
FIG 12: Remove top plate. Turn it upside down and
undercut strips joining the lid with the top plate in order
to weaken it. Remove the lid by pilers or other tool and
place the top plate.
In order to change to a posterior mounted flue you
need to:
FIG 13: Remove the perforated decoration lid in the
back with a hammer, or a hacksaw. Remove a
heat protection perforated cover B. Unscrew
the rear sheet steel lid C. Unscrew the top
collar D. The draft diverter will also losen.
Open
Closed
Open
Closed
Fasten the sheet steel lid and the draft diverter
on the top flue outlet. Fasten the collar on the
posterior flue F. Put on the top plate.

Connection of the flue

Please be aware when connecting the
the smoke dome that the flue is placed inside the flue
outlet collar. Use stove cement in the joints. For the flue
connection to the chimney, follow the recommendations
from the chimney manufacturer.
Air supply
FIG 14-17: The possibility to connect a fresh air
supply ducting set (Fig Quadro Air =mm)

5. Lighting the fire for the first time

When the stove is assembled and all instructions
have been observed, a fire can be lit. Be careful with
touching the stove the first few times it is used as it
may damage the varnish. Take care when inserting
logs into the burn chamber, in order not to damage
the Thermotte plates. Please note that during the first
few firings, the insulations panels within the firebox
will release moisture contained within them from
production. This will slow down the burn rate slightly
and could cause markings on the glass. These are
easily removed with glass cleaner once the glass has
gone cold. Possibly leave the door slightly open the
first 2-3 times that the stove is used. It is advisable to
ventilate the room well when making the fire for the
first time as the varnish on the stove will release
some smoke or smell. Both the smoke and smell will
disappear and are not hazardous. When lighting the fire
for the first time we also recommend opening/shutting
the door regularly the first two hours to aviod the door
gasket sticking to the varnish.
Lighting a fire
Insert small dry pieces of kindling wood, ignite and
ensure that the flames have established before closing
the door. Open the air vent control before you close the
door. Additional ignition air is obtained by leaving the
door slightly open. When the flames are stable and the
chimney is warm, the air supply is regulated with this
air vent control so that the stove and chimney do not
become overheated.
When there is a glowing layer of ash, new wood logs
can be inserted. Remember to pull the hot ember
forward in the burn chamber when inserting new logs
so that the wood is ignited from the front. Open the vent
or leave the door slightly open each time new logs are
inserted so that the flames get established. The fire
should burn with bright and lively flames.
Using the stove with low combustion effect increases
pollution as well as the risk of a fire in the chimney.
Never allow the stove or flue to become glowing
red. Turn off the air vent control should this happen.
Regulation of the air vent control takes some
GB
150
mm flue to
11