Technical Information Ni; Distance To Combustible Material; Assembly; Fax: (+47) 32 24 - Nordpeis NI-22 Manuel D'installation

Masquer les pouces Voir aussi pour NI-22:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
floorboards under the fireplace should be removed to
avoid that the floorboards lock and crack.

2. Technical Information NI-22

The inserts from Nordpeis have secondary
combustion and are clean burning. The combustion
takes place in two phases: first the wood burns and
then the gases from the fumes are lit by the hot air.
This ensures that these new inserts have minimal
emissions of soot particles and unburnt gases (such
as CO) and are thus better for the environment. Clean
burning inserts require a small amount of wood in
order to obtain a good heat output. Use exclusively
clean and dry wood. We recommend seasoned
hardwood with a maximum moisture content of 20%.
Insert:
NI-22
Material:
Cast iron
Surface treatment
Heat resistant varnish
door / doorframe:
Fuel:
Wood logs, 35 cm
Operating range:
2-10 kW
Ignition vent control and air
Draught system:
vent control
Secondary combustion
Combustion system:
(clean burning)
Heating area:
30-150 m²
Flue outlet:
Top, posterior and lateral
Inner Ø 150 mm
Flue:
(NB! In UK outer Ø)
Weight of insert:
108 kg
Area of convection
400 cm²
air vent under insert:
Area of convection
600 cm²
air vent over insert:
Warning: If the requirements for ventilation are
NOT complied with, the heating circulation effect
will be considerably reduced and
overheating can occur.
This can in a worst case scenario cause a fire.

3. Distance to Combustible Material

Ensure that the safety distances are respected
(FIG 1).
The distance between the top of the convection air
outlet and roof of inflammable material must be at
least 500 mm.The distance from the front of the insert
to furniture needs to be of at least 1 metre. When
connecting a steel chimney to the top outlet use the
security distances required from the manufacturer.
All manuals and user guides at all-guides.com

4. Assembly

The following tools are necessary:
1. Ensure that all the loose parts are included (FIG 2):
A.
B.
C.
D.
E.
F.
G.
H.
2. Carefully lay the insert on its back. Ensure that
Start with assembling the legs (FIG 3) as follows:
3. Install the smoke dome (FIG 5A). The dome is
GB
Important! When placing the insert on a
combustible floor, a steel plate of at least 0.7mm
must cover the entire floor surface inside the
surround. Any flooring made of combustible
material, such as linoleum, carpets etc. must be
removed from underneath the steel plate.
10 mm and 13 mm spanner/wrench
Electrical drill / Phillips screwdriver (for self tapping
screws)
Caulking gun (for the stove cement)
Heat shield in two parts with 4 self drilling screws
Lid for flue outlet with fastening bracket, screw and
nut
Smoke dome
2 fasteners with bolts and disks for the smoke
dome
Insert with door
3 fastening bolts with disks for the legs
3 legs with adjusting bolts and lock nuts
Glove
The insert expands when in use, and for this
reason the insert must NEVER rest on the
surround, but have a gap of about 3 mm. The
insert must neither rest on the bench plate or
against the sides. It is recommended to dry
stack the surround in order to adjust the insert
prior to perforating the chimney for the flue
connection.
the transportation padding is put inside the insert
before turning it over, so that the insulating plates
in the burn chamber do not fall down and break.
Please note that the insulating plates may release
coloured dust when touched. Avoid touching the
cast iron with dust on your fingers. In case of dust
on any cast iron part, the glove included is well
suited to brush it off.
Fasten the screws on to the insert with a 13 mm
spanner/wrench. The legs are placed as shown
(the opening in the legs should face outwards).
Use the adjusting bolts (FIG 4) and adjust the legs
to the desired height (X) before returning the insert
to an upright position (do not tilt the insert). The
height depends on the surround.
Regulation of leg height (X) for NI-22:
From: 240 mm To: 380 mm.
assembled with a fastener on each side. Use a 10
mm spanner/wrench and the fastening disks and
11

Publicité

Table des Matières
loading