8.2
Ordinary maintenance
Carry out, at least once a year by skilled personnel, a general check of the glasses opening
system, on the electric system and on the refrigerating circuit.
Should it be necessary to top up with refrigerating gas, use a station equipped with two ¼ SAE
valves, to screw on the appropriate fittings placed near the compressor.
Follow the below steps to replace a fluorescent lamp:
• Pull the plug out.
• Remove protection "1".
• Slide the lampholders "2" at both ends.
• Replace the lamp and re-install everything
correctly.
8.3
Extraordinary maintenance
Any other operation not listed in the previous point, must be carried out by skilled personnel.
9. WASTE DISPOSAL
The waste disposal operation of the display case must be carried out in compliance with regulations
relating to waste disposal applicable in individual countries. All informations on the materials used for
manufacturing the display case can be required directly to Euro'cryor.
Before proceeding with the display case waste disposal, we recommend to entrust a specialized
company for collecting the refrigerant and the oil which is in the cooling system.
Periodically check the normal downflow of the
condensing water.
22